Stay Time
The Stay Time is how much time remains, at
the current Dose Rate, before the High Dose
Alarm is triggered. Stay Time is calculated by
dividing (the High Dose Alarm Setpoint
minus the already accumulated Dose) by the
current Dose Rate, then converting the result
to minutes. If the display reads 999, the
maximum, your Stay Time is at least 16.5
hours.
WARNING:
If the Dose Rate goes up,
your remaining Stay Time
will go down.
You should check your
Stay Time frequently when
you are in the presence of
radiation.