NV9607 Control Panel • User’s Guide
21
4. Configuration
Panel Options
Checkbox Options
The checkbox options section is just below the panel options section, enclosed in the same region:
A check in the box enables the option. Clearing the checkbox disables the option.
By default, all the check box options are clear.
The following items are the checkbox options:
• User-Programmable ID.
Allows the Panel ID to be changed locally at the control panel (in menu mode).
• Source Master Default.
Makes a control-level source the
controlling
device (or master device) by default. Otherwise,
the destination is the master by default. (The option is specifically for use with NVISION series
machine control routers.)
“Source is master” is used for duplication, or broadcast routing, on a machine control level.
“Destination is master” is for machine-to-machine editing. If you do not select the “source mas-
ter default” option, you can place a ‘Source is Master’ button on the panel.
S
Note:
a ‘Source is Master’ button is a toggle that reverses the direction of data routing for
devices used in data level (machine control) takes.
• Hold preset default.
When this checkbox is checked, the panel powers up in “hold mode.” Otherwise it powers up
with hold mode off.
Hold mode, under single-destination mode with breakaway, causes the selected levels to be
retained after a take. If hold mode is off, all levels become selected after a take.
Data
Routing Mode
Automatic
If a control (data) level is involved in the route, make the route on the
control level even if the control port is in use on the source or
destination device.
Semi-automatic
(recommended)
If the control port is in use on the source or destination device, take
all levels except control and allow the user to perform the control
level route by pressing ‘Take’ a second time. If ‘Take’ is not pressed
again, the route is cancelled.
If the control port is not in use, the control level take occurs
automatically.
Manual
A take on the data level must be performed manually as a breakaway
on the control level. The control level will never switch as part of a
multi-level take.
Default Name Set System Name
A list of “name sets” appears in the drop-down menu. The name sets
can be defined under the System Management pane of NV9000-SE
Utilities. Choose ‘System Name’ in this list if you do not want, or do
not care about, alternate device names. Do
not
choose ‘System
Name’ if you are configuring any ‘Name Set Toggle’ buttons.
Содержание NV9606
Страница 10: ...x Rev 1 0 21 May 10 Table of Contents ...
Страница 20: ...10 Rev 1 0 21 May 10 2 Introduction Other NV9607 Functions ...
Страница 40: ...30 Rev 1 0 21 May 10 4 Configuration Multi Destination Configuration ...
Страница 66: ...56 Rev 1 0 25 May 10 5 Operation Setup Mode ...
Страница 72: ...62 Rev 1 1 21 May 10 6 GPIO Configuring Inputs ...
Страница 82: ...72 Rev 1 0 21 May 10 8 Misc Topics Power Cord Retention ...
Страница 90: ...80 Rev 1 0 18 Aug 10 Index ...