31
1
Incoming water flow too low for appliance to
operate safely, faulty Thermal Trip or faulty
heater Tank.
1.
reset / recommission the shower.
2.
check all plumbing isolator valves to the
shower are turned fully on.
3.
check water pressure.
4.
a section of the supply pipe is frozen, allow
to thaw and insulate the pipe.
5.
replace Thermal Trip.
6.
replace heater Tank.
2
problem with electrical supply, faulty control pcb
or faulty relay board.
1.
reset / recommission the shower.
2.
replace Thermal Trip.
3.
replace control pcb
4.
replace relay board.
3
4
appliance has been incorrectly shut down.
1.
reset the shower.
refer to section:
'operation, using the
shower'
for correct shutdown procedure.
control pcb failure.
1.
reset / recommission the shower.
2.
replace control pcb.
5
appliance has been incorrectly shut down.
1.
reset the shower.
refer to section:
'operation, using the
shower'
for correct shutdown procedure.
Incoming water temperature too high, faulty
control pcb or faulty Flow valve assembly.
1.
reset / recommission the shower.
2.
check mains water temperature.
3.
replace Flow valve assembly.
4.
replace control pcb.
6
Flow valve assembly is disconnected or faulty.
1.
reset / recommission the shower.
2.
check Flow valve connection.
3.
check Multiway cable connection.
4.
replace Flow valve assembly.
5.
replace control pcb.
6.
Frozen unit.