background image

Code No. 0816154

Rev. 2a (10/08)

INSTALLATION INSTRUCTIONS FOR

ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

LIMITED WARRANTY

Sloan Valve Company warrants its ETF-660 and ETF-770 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the
service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of
purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer's
cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or
organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of resale.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
OF ANY MEASURE WHATSOEVER.

PRIOR TO INSTALLATION

Prior to installing the Sloan ETF-660 or ETF-770 Faucet, install the
items listed below. Also, refer to the Rough-In. 

• When Using Plug-In Transformer — Install electrical receptacle for plug-

in transformer (120 VAC, 2 amp service for each ETF-233 (24 VAC, 35
VA) plug-in transformer used).

• When Using Box Mount Transformer — Install electrical wiring to

transformer location (120 VAC, 2 amp service for each EL-248-40 (24
VAC, 40 VA) transformer used).

• Lavatory/sink
• Drain line
• Hot and cold water supply lines or tempered water supply line

Multiple Faucets

Multiple faucets can be powered by a single transformer, provided that the
transformer has been properly sized. Allow a minimum of 15 VA of current
rating for each solenoid valve used. Refer to “Step 5 — Install Transformer”
for further information.

Mixing Valve

When installing the faucet with a Sloan mixing valve, these Installation
Instructions AND the Installation Instructions packaged with the mixing valve
MUST be followed.

Important:

• INSTALL ALL ELECTRICAL WIRING IN ACCORDANCE WITH

NATIONAL/LOCAL CODES AND REGULATIONS.

• INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES

AND REGULATIONS.

• A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED.
• USE APPROPRIATE PRECAUTIONS WHILE CONNECTING TRANSFORMER

TO 120 VAC POWER SOURCE.

• DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE)

UNTIL ALL WIRING IS COMPLETED. ALLOWING 24 VAC TRANSFORMER
WIRES TO TOUCH OR SHORT WHILE POWER IS BEING SUPPLIED WILL
CAUSE PERMANENT DAMAGE TO THE TRANSFORMER AND CIRCUIT
CONTROL MODULE.

• KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT

COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS. FOR THREADED PIPE FITTINGS, DO NOT
APPLY SEALANT TO THE FIRST TWO “STARTER” THREADS.

• FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING

SOLENOID TO SUPPLY STOPS.

TOOLS REQUIRED FOR INSTALLATION

• Open end wrenches for hex sizes: 15/16”, 13/16”, 11/16”, 7/8” & 5/8”
• Basin wrench
• Slotted screwdriver, 3/16”
• Slotted screwdriver (supplied)
• Phillips head screwdriver, #2
• Pliers
• Wire stripper/crimping tool

INSTALLATION OF ETF-660 AND ETF-770 FAUCETS

Bak-Chek

®

Tee Usage

When connecting the Sloan ETF-660 or ETF-770 Faucet to both hot and cold
water supplies, a Bak-Chek

®

Tee is provided and required. Water temperature

can be controlled by adjusting the supply stops. Refer to Rough-in
illustrations on Page 2.
When connecting the faucet to a single line water supply or a pre-tempered
water supply, a Bak-Chek

®

Tee is not required.

A Bak-Chek

®

Tee is not required or provided when a Temperature Mixing Valve

is included with the faucet.

Compliant to: 
ASME A112.18.1 and CSA B125.1

ETF-770

Sensor Activated Electronic

Gooseneck Faucet for tempered

or hot/cold water operation.

ETF-660

Sensor Activated Electronic

Lavatory Faucet for tempered

or hot/cold water operation.

Содержание ETF-660

Страница 1: ...ng for each solenoid valve used Refer to Step 5 Install Transformer for further information Mixing Valve When installing the faucet with a Sloan mixing valve these Installation Instructions AND the Installation Instructions packaged with the mixing valve MUST be followed Important INSTALL ALL ELECTRICAL WIRING IN ACCORDANCE WITH NATIONAL LOCAL CODES AND REGULATIONS INSTALL ALL PLUMBING IN ACCORDAN...

Страница 2: ...t with BDM and BDT Variation Mixing Valves for Hot and Cold Water Supply shown with 4 trim plate ETF 770 Faucet with Bak Chek Tee for Hot and Cold Water Supply shown with 4 trim plate ETF 770 Faucet with ADM Variation Mixing Valve for Hot and Cold Water Supply shown with 4 trim plate ETF 770 Faucet with BDM and BDT Variation Mixing Valves for Hot and Cold Water Supply shown with 4 trim plate ETF 6...

Страница 3: ...LL BEVEL SIDE DOWN NUT TRIM PLATE FAUCET SHANK SPOUT TRIM PLATE OPTIONAL WASHER NUT SPOUT ETF 660 FAUCET ETF 770 FAUCET TRIM PLATE OPTIONAL WASHER NUT FAUCET SHANK RUBBER WASHER 4 Connect Supply Line s Note If installation includes a Sloan mixing valve refer to the Installation Instructions supplied with the Sloan mixing valve Flush dirt debris and sediment from the supply line s FOR DUAL LINE HOT...

Страница 4: ... Faucet 18 gauge wire is recommended A Run wires from secondary side of Transformer to 3 8 inch 10 mm hole at back of Control Module Enclosure If necessary wires can be run through wall and then inserted through hole in back of Control Module Enclosure Plug in Transformers Important DO NOT plug Transformer into receptacle until all wiring has been completed The Transformer is supplied with a 10 fo...

Страница 5: ...LOTS FROM FAUCET SPOUT TERMINAL BLOCK 1 REMOVE TERMINAL BLOCK 2 INSERT POWER CABLES 3 SECURE WITH SCREWS 4 REINSTALL TERMINAL BLOCK CONNECTOR BOARD POWER CABLE MODULAR RECEPTACLE B Insert Solenoid Valve Connector into the Modular Receptacle on Connector Board D Insert each Conduit Cable into a strain relief slot in the Control Module 8 Plug In Transformer A Plug Transformer into 120 VAC Receptacle...

Страница 6: ...ime Out by configuring the number 1 2 and 3 Dip Switches as shown in Table 1 Table 1 Time Out Settings Unless otherwise specified all ETF 660 ETF 770 Faucets leave the factory set with a 30 second Time Out Note The position of Dip Switch 4 range enhancer setting does not affect Faucet Time Outs Push Cables into slots at the bottom of the Control Module Install Control Module cover using Screws pro...

Страница 7: ...eering Department at 1 888 SLOAN 14 1 888 756 2614 OR 1 847 233 2016 Note Remove Cover from Control Module to check diagnostic lights 1 PROBLEM No water is delivered when Faucet is activated INDICATOR If no LED lights illuminate CAUSE No electricity is being supplied to Faucet SOLUTION Ensure that the main power is turned ON Check all Transformer Sensor Solenoid and Cable Connections Make sure tha...

Страница 8: ...l Mixing Valve not shown Item Part Description No No OPTIONAL MIXING VALVES 13 MIX 60 A Below Deck Mechanical Water Mixing Valve BDM Variation 14 MIX 135 A Below Deck Thermostatic Water Mixing Valve BDT Variation 15 MIX 110 AA Optimix Deck Mounted Water Mixing Valve FAUCET CABLE EXTENSION CORDS Faucet to Control Module Solenoid to Control Module ETF 1005 26 26 0 7 meter Length ETF 1003 36 36 0 9 m...

Отзывы: