33
12
outlet Sensor disconnected from relay board or
faulty control pcb.
1.
reset / recommission the shower.
2.
check outlet Sensor connection to relay
board.
3.
check Multiway cable connection.
4.
replace control pcb.
5.
replace heater Tank
13
note! This failure only occurs during
commissioning
possible heater Failure.
1.
reset / recommission the shower.
2.
check resistance of heater Tank
elements.
3.
check operation of relays / replace relay
board
4.
replace heater Tank assembly with an
appropriately rated spare.
5.
replace Flow valve.
14
appliance has been incorrectly shut down.
1.
reset / recommission the shower.
15
LIGhTS FLaShInG In
pecULIar WaYS.
power Supply failure.
1.
replace relay pcb.
2.
check Multiway cable connector.
3.
check control pcb.
16
prodUcT drIppInG
When no poWer To
UnIT.
1.
check Filters for debris.
2.
check water pressure.
3.
change Flow valve and Filter.
17
prodUcT cUTTInG oUT
(erraTIc operaTIon).
Water ingress.
1.
Isolate and check case / cover for correct
fitment.