NOTE: Following any troubleshooting, reset the system by cycling power. If
the suggested remedial action does not resolve the problem and the system
continues to not function properly, contact your service provider for further
assistance.
Maintenance
The MIOX RIO Zuni is designed for minimal maintenance. As long as the water and brine
supplies are within the specifications, there should be almost no maintenance required to
keep the unit running.
Salt Loading
Salt load will be required to maintain saturated brine levels. The conversion efficiency for
the RIO Zuni is 3.0 – 3.5 lb./kg salt per lb./kg FAC. This means 300 lbs of salt will provides
enough brine for up to 100 lbs mixed oxidant production. This equates to 12 to 16 weeks of
continuous operations of a RIO Zuni 1 lb. system or 6 to 8 weeks of continuous operation of
a RIO Zuni 2 lb. system.
General Plumbing Checks
The RIO Zuni comes preassembled with secured plumbing connections which should never
require replacement; however, if any of the internal plumbing connections are broken, the
connections should be resealed with zip ties or hose clamps.
Changing Peristaltic Pump Tubes
Other maintenance which might be necessary is changing the peristaltic pump tubes for the
water and brine pumps. The pump tubes should be changed if overall system flowrate falls
below 50% of the specified flow or if liquid is seen running out of the system housing.
To change the peristaltic pump heads, remove the system cover and find the two peristaltic
pumps. The system cover is held to the base with four screws on the bottom corners of the
cover (See Figure 10). Once the cover is removed and the pumps are accessible, change the
tubes by following the instructions included in the Appendices of this manual, Changing
Pump Tubes.
Caution should be taken to prevent accidental exposure of brine and oxidant to
skin or eyes when servicing the unit. If this occurs, rinse affected areas with
water and apply first aid as needed.
Always disconnect power from unit before removing cover.
Safety
Safety
Содержание RIO Zuni 1
Страница 18: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 18 Figure 8 RIO Zuni Connections...
Страница 35: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 35...
Страница 36: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 36...
Страница 37: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 37...
Страница 38: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 38...
Страница 39: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 39...