![MIOX RIO Zuni 1 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/miox/rio-zuni-1/rio-zuni-1_installation-operation-and-maintenance-manual_1804807016.webp)
MIOX RIO Zuni™ Operators Manual
P/N: 102-00094-I
Page 16
1)
MIOX RIO Zuni OSG
2)
5 foot by 5 foot indoor environment
3)
110-240 VAC 10A circuit with standard grounded wall plug
4)
Saturated Brine Supply (see MIOX Salt Quality Guidelines for salt
specifications)
5)
Fresh Water Supply (see Appendices for Water Quality Guidelines)
6)
Oxidant Storage Tank with Hydrogen Venting (see Hydrogen Safety White
Paper for details)
7)
Tubing and hose clamps (provided with OSG)
8)
Level Switch Assembly (provided with OSG)
9)
Power Cord (provided with OSG)
Tools for install
The MIOX RIO Zuni can be installed without any tools, although MIOX recommends using a
pair of pliers to tighten the hose clamps on the plumbing I/O panel.
Refer to the Integrated Brine Tank Manual for tools needed to install the Integrated
Brine Tank.
Refer to the Oxidant Tank Manual for tools needed to install the Level Switch Assembly.
Installation Location Requirements
The RIO Zuni OSG must be installed indoors on a flat level surface approximately 5 feet long
by 5 feet wide (1.52m by 1.52m). The ambient air temperature at the installation location
must be between 40°F (5°C) and 110°F (43°C). Additional space may be required for the
water, brine, and oxidant tanks. MIOX recommends placing the OSG and tank near an
available drain for ease of draining the tank or in case of minor overflows. Additionally,
MIOX recommends placing the RIO Zuni near an external wall for ease of hydrogen venting
as described in the Hydrogen Safety White Paper.
NOTE: Failure of the system that can be traced to improper
temperature conditions is not covered under the MIOX warranty.
Connections
Plumbing
The RIO Zuni has three barbed plumbing connections on the plumbing I/O panel: water
inlet, brine in, and oxidant out. The ¼” barbed water inlet must be connected to the
appropriate location on the included Inline Pressure Reducer Kit. The ¼” barbed brine inlet
must be connected to an unpressurized saturated brine supply.
If using the integrated brine tank with the RIO Zuni OSG, the water and brine inlets
will connect to the labeled water and brine outlets on the integrated brine/water
tank. Please refer to the Integrated Brine Tank Manual for more details.
Содержание RIO Zuni 1
Страница 18: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 18 Figure 8 RIO Zuni Connections...
Страница 35: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 35...
Страница 36: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 36...
Страница 37: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 37...
Страница 38: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 38...
Страница 39: ...MIOX RIO Zuni Operators Manual P N 102 00094 I Page 39...