- 29 -
Command packet
Comment
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a command
with illegal command parameters is accepted
Command Not Executable
z0 61 41 FF
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
5.2 VISCA Protocol Device Control Command
Command
Function
Command packet
Comment
AddressSet
Broadcast
88 30 0p FF
p: Address setting
IF_Clear
Broadcast
88 01 00 01 FF
I/F Clear
CommandCancel
8x 21 FF
CAM_Power
On
8x 01 04 00 02 FF
Power ON/OFF
Off
8x 01 04 00 03 FF
CAM_Zoom
Stop
8x 01 04 07 00 FF
Tele(Standard)
8x 01 04 07 02 FF
Wide(Standard)
8x 01 04 07 03 FF
Tele(Variable)
8x 01 04 07 2p FF
p = 0(low) - F(high)
Wide(Variable)
8x 01 04 07 3p FF
Direct
8x 01 04 47 0p 0q 0r 0s FF
pqrs: Zoom Position
CAM _Focus
Stop
8x 01 04 08 00 FF
Far(Standard)
8x 01 04 08 02 FF
Near(Standard)
8x 01 04 08 03 FF
Far(Variable)
8x 01 04 08 2p FF
p = 0(low) - F(high)
Near (Variable)
8x 01 04 08 3p FF
Direct
8x 01 04 48 0p 0q 0r 0s FF
pqrs: Focus Position
Auto Focus
8x 01 04 38 02 FF
Manual Focus
8x 01 04 38 03 FF
One Push mode
8x 01 04 38 04 FF
CAM _Zoom Focus
Direct
8x 01 04 47 0p 0q 0r 0s
0t 0u 0v 0w FF
pqrs: Zoom Position
tuvw: Focus Position
CAM_AFSensitivity
High
8x 01 04 58 01 FF
Focus sensitivity Setting
Normal
8x 01 04 58 02 FF
Low
8x 01 04 58 03 FF
CAM_AFZone
Top
8x 01 04 AA 00 FF
Focus Region Setting
Center
8x 01 04 AA 01 FF
Bottom
8x 01 04 AA 02 FF
ALL
8x1 01 04 AA 03 FF
CAM_WB
One Push mode
8x 01 04 35 03 FF
One Push Trigger
8x 01 04 10 05 FF
One Push WB Trigger(Enabled during One
Push WB mode)
CAM_WB Mode
8x 01 04 35 pq FF
pq = 00--33 WBMode
CAM_AWBSensitivity
Low
8x 01 04 A9 00 FF
WB Sensitivity Setting
Normal
8x 01 04 A9 01 FF
High
8x 01 04 A9 02 FF
CAM _RGain
Reset
8x 01 04 03 00 FF
Manual Control of R Gain
Up
8x 01 04 03 02 FF
Содержание UV401
Страница 1: ...4K Ultra HD PTZ Camera User Manual V1 0...
Страница 23: ...22 3 English Menu...
Страница 24: ...23...