FrameMaker Ver.5.5(PC) EP3000/EP3010 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.05.29
S-5
33
FUNCTIONS OF SWITCHES AND POINTS ON PWB
33-1. PWB Location
33-2. Master Board PWB-A
Symbol
Name
Description
S1
Trouble Reset Switch
Resets a malfunction including those of the Exposure
Lamp (C04XX) and fusing (C05XX).
PJ29
Initialize Switch
Forcibly resets a misfeed or malfunction that occurred
due to incorrect operation, etc. when it cannot be
reset by opening and closing the Front Door or the
press of S1.
TP2
GND Test Point
Ground terminal used for memory clear.
TP3
Memory Clear Test Point Initializes all data except the counts of electronic
counters, access numbers and administrator number
for Copy Track, and RD mode functions.