FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-36
(5) Cleaning of the Image Transfer/Paper Separator Coronas Housing
(6) Cleaning of the Lower Pre-Image Transfer Guide Plate
(7) Replacement of the Ozone Filter
1. Remove the four Paper Guides.
2. Remove the two End Caps.
3. Remove the Image Transfer and Paper Separator
Corona Wires.
NOTE
When removing the Wire, unhook the spring end first
and use care to prevent breaking and deformation.
(Use a pair of tweezers.)
Keep the Corona Wire Cleaning Lever (for the Image
Transfer Corona) pressed all the way back in. Do not
attempt to remove the Lower Pre-Image Transfer
Guide Plate as it has been adjusted for correct height.
4. Using a soft cloth dampened with alcohol, wipe the
Housing clean of dirt.
1151D037AA
1139D181AA
1151D037AA
1139D182AA
Using a brush, whisk dust off the Lower Pre-Image
Transfer Guide Plate.
1139D183AA
1. Press the Filter Cover Bracket in the direction of
the arrows and pull it off.
2. Remove the Filter and replace it with a new one.
1151D045AA