FrameMaker Ver.5.5E(PC) EP3000/EP3010 TROUBLESHOOTING
98.08.06
T-33
AD-11 Storage Misfeed Troubleshooting Procedure
Symptom
Step
Check Item
Result
Action
The leading edge
of the paper is sta-
tionary inside the
Duplex Unit.
1
Is the Paper Guide Mylar dirty
or deformed?
YES
Clean or replace the Mylar.
2
Does PC14 operate properly?
Using the IC Port Data Check
function, make an input port
check on PWB-A (Dup) (IC1G)
PC1.
YES
Replace PWB-G, PWB-A or
PWB-A (PF-206, PF-112).
NO
Check the operation of the
actuator of PC14. If it operates
properly, replace PC14.
3
Does SL31 operate properly?
Using the IC Port Data Check
function, set the data of PWB-
A (Dup) (IC1G) PH1 to “0”.
YES
Check the operation of the
Gate Switching Lever.
NO
Replace PWB-G, PWB-A,
PWB-A (PF-206, PF-112) and/
or SL31.
Paper is station-
ary at the Storage
Section.
1
Does PC15 operate properly?
Using the IC Port Data Check
function, make an input port
check on PWB-A (Dup) (IC1G)
PC2.
YES
Replace PWB-G, PWB-A or
PWB-A (PF-206, PF-112).
NO
Check the operation of the
actuator of PC15. If it operates
properly, replace PC15.
Содержание EP3000
Страница 1: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 GENERAL ...
Страница 16: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 MECHANICAL ELECTRICAL ...
Страница 154: ...FrameMaker Ver 5 5E PC EP3000 EP3010 DIS REASSEMBLY ADJUSTMENT 98 05 29 EP3010 DIS REASSEMBLY ADJUSTMENT 18605 ...
Страница 235: ...FrameMaker Ver 5 5E PC EP3000 EP3010 TROUBLESHOOTING 98 08 06 EP3010 TROUBLESHOOTING 10794 ...