FrameMaker Ver.5.5(PC) EP3000/EP3010 SWITCHES ON PWBs/TECH. REP. SETTINGS
98.05.29
S-28
[Tech. Rep. Mode
Counter]
Touch Panel Display
Operation
Trouble
<Trouble Counter 5/5>
<Clearing a Count>
Using the
or
key, highlight the count to be cleared, then press
the Clear key.
NOTE
If a count is accidentally cleared, pressing the Interrupt key will
undo the clear operation.
Maintenance
Five different values (counts) can be set for the Maintenance
Counter. Each counter is increased by 1 each time a copy is made
and, when the preset count is reached, the maintenance call
reminder message and maintenance code “M1” appear on the
Touch Panel.
NOTE
Whether the maintenance call reminder message is given or not
depends on the setting made for “Maintenance” of “Tech. Rep.
Choice.” Also, copying is not inhibited even when the reminder
message appears.
<Setting a Count>
1. Using the
or
key, select the counter to be set.
2. Enter the value from the 10-Key Pad.
<Clearing the Set Value/Count>
Using the
or
key, highlight the count to be cleared, then press
the Clear key.
NOTE
If a count is accidentally cleared, pressing the Interrupt key will
undo the clear operation.
▲
Malfunction Code
Location
C0b7X
C0d00
C0d20
C0d5X
Sorter (Punch)
Front/Rear Guide
Dup Storage
Dup Drive Motor
▲
▲
▲
▲
▲
▲
Содержание EP3000
Страница 1: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 GENERAL ...
Страница 16: ...FrameMaker Ver 5 5E PC EP3000 EP3010 GENERAL MECHANICAL ELECTRICAL 98 06 10 EP3010 MECHANICAL ELECTRICAL ...
Страница 154: ...FrameMaker Ver 5 5E PC EP3000 EP3010 DIS REASSEMBLY ADJUSTMENT 98 05 29 EP3010 DIS REASSEMBLY ADJUSTMENT 18605 ...
Страница 235: ...FrameMaker Ver 5 5E PC EP3000 EP3010 TROUBLESHOOTING 98 08 06 EP3010 TROUBLESHOOTING 10794 ...