90
Data Processor
Measurement
Color Difference Measurement
The instrument can measure the color difference between the color difference target color and a speci-
men using color spaces,
∆
(XYZ),
∆
(Yxy),
∆
(L*a*b*),
∆
Hunter Lab,
∆
(L*C*H), and others. (See P.78
“Selecting the Color Space” for details.)
<Setting the Color Difference Target Color>
Before measuring color difference, you must set the color difference target color in the measuring
head. 100 color difference target colors can be set to nos. T00 to 99.
The color difference target color number can be changed to a name for the sake of convenience.
The color difference target color number can be set independently of the page function (P.105).
Setting color difference target colors should be done under the same temperature conditions
as calibration and measurement.
There are two ways to set the color difference target color.
1) Measuring a specimen and setting the data as the color difference target color
2) Using the keys to set the color difference target color
1) Measuring a specimen and setting the data as the color difference target color
Bofore Measurement
•
Select the color space and screen for your use.
See P.78 “Selecting the Color Space”, and P.81 “Screen Display and Changing the Display”
for details.
Operating Procedure
1
Press the Target Color key
Target
Symbol
while in the measure-
ment screen.
•
The color difference target color setting screen appears.
•
The first color difference target color is set to T00. (Target
color name T00 can be changed.)
•
To set the color difference target color to the currently selected
color difference target color number, go to step 6.
Color difference
target color name
Color difference
target color is set
to T00.
POWER
Ready lamp
Color difference target
color specimen
3,4,
6,8
6
5
7
3,4
1
2
[TARGET]
◎TARGET VALUE
L*=
a*=+ 15.32
b*=+ 10.21
◎TARGET NAME A
T00
DISP. LIST:[Esc]
P00
C P
[0001]
74.72
Содержание CR-400 -
Страница 23: ...21 Chapter 1 Measuring Head 1 This chapter describes how to use the measuring head alone...
Страница 54: ...52...
Страница 59: ...57 Chapter 3 Data Processor This chapter describes how to use connected the Measuring Head and Data Processor...
Страница 143: ...141 Chapter 4 Description...
Страница 156: ...154 Description Dimensions Measuring Head Unit mm CR 400 Head 217 63 102 40 2 32...
Страница 157: ...155 Description Unit mm CR 410 Head 67 5 244 63 102 32...
Страница 158: ...156 Description Data Processor Unit mm DP 400 Dimensions 100 255 73...