16
FLOW & PRESSURE SENSOR
( INSTRUCTION MANUAL )
MFP01
How to use
–
Functions instructions
Function
code
Item
Default setting
Explanation
F-07
rEFE
Flow reference standard selection
rEFE
Select the flow value is shown
under standard (ANR) or normal
condition ( NOR ).
rEFE
Flow reference standard selection
Anr
F-08
RnG
Analog output selection
AnG
Select the analog corresponding to
pressure or flow sensor.
FLoy
Analog output selection
FLoy
F-09
EEPr
Accumulated value hold selection
EEPr
To save the last accumulated flow
value every 2 or 5 minutes.
EEPr
Accumulated value hold selection
oFF
F-10
d1s
Flow sensor display mode selection
d1s
Select to display Instantaneous
Flow or Accumulated Flow Mode.
dsp
Flow sensor display mode selection
1nS
F-91
ECo
Power-Save mode selection
ECo
Select if turn on powersave
mode to reduce power consumption.
ECo
Power-Save mode selection
no
F-92
1nP
External input selection
1nP
Select for Accumulated flow
rate zero clear, Auto-Shift or Auto-
Shift zero.
1nP
External input selection
r_r
F-93
AbUS
Modbus RTU setting
AbUS
Set ID number, baud rate and
transmission format.
1d
ID number setting
1
rAt
Baud rate setting
96
(9600 Bd)
For
Transmission format setting
n81
trR
Communications protocol setting
rtU
F-94
F1nE
Fine adjustment setting
F1nE
The displayed value can be
adjusted slightly.
F1nE
Fine adjustment setting
oFF
F-95
FoUt
Forced output function
FoUt
To turn the analog ON / OFF
forcibly.
oUt1
Forced output function
oFF
oUt2
Forced output function
oFF
F-99
rESt
Reset to the default setting
rESt
Return to the factory default setting.
rSt
Reset to the default setting
oFF
Item
Explanation
Pressure display
Display pressure value.
Flow display
Display instantaneous flow rate.
Accumulated flow rate display
Display accumulated flow rate.
Pressure zero setting
The displayed pressure value can be adjusted to "0".
Instantaneous flow rate zero setting The displayed instantaneous flow rate value can be adjusted to "0".
Accumulated flow rate zero clear
The accumulated flow rate can be set to "0".
Peak value display
The maximum pressure or instantaneous flow can be detected when the power is supplied for
a period.
Bottom value display
The minimum pressure or instantaneous flow can be detected when the power is supplied for
a period.
Key lock / unlock mode
To prevent errors occurring due to unintentional changes of the set values.
Measurement mode