background image

3

Precaution

To ensure safe operation, please read this service manual carefully before use. When designing and 

manufacturing equipment using Mindman products, the manufacturer is obligated to ensure that the 

safety of the mechanism, pneumatic control circuit and/or air control circuit and the system that runs 

the electrical controls are secured.

Explanation of label

Observe the warnings and cautions on the following pages to prevent accidents. These instructions 

indicate the level of potential hazard by labels of "

WARNING

" or “

CAUTION

”. Note that some items 

indicated with “

CAUTION

” may lead to serious results depending on the conditions. All items 

contain important information and must be observed.

The product characteristics are confined to no flow in the pipeline. When air is consumed on 

the output side, pressure may become unstable.
In order to avoid the error caused by noise, please take the following measures:

Set the line filter on AC power line to remove the power noise.
Keep the product away from the engine and power line to avoid noise affects.
Induced charge (like solenoid valve, relay), must prevent them from negative charge.
In order to avoid the effects of power fluctuation, please cut off the power before plug 

the connector.

The cable plug is four-core wire. When the monitor output is not being used, prevent it from 

touching the other wires as this can cause a malfunction.
Please note that the right angled cable connector does not rotate and is limited to only one 

entry direction.
Use clean compressed air that does not contain corrosive gas. Poor air quality adversely 

affects function and life.
Do not use a lubricator on the supply side of this product, the lubricated air might cause 

malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the 

output side of the equipment and set a check valve. When the secondary pressure is lowered 

with an input signal, etc., the secondary air passes through the product and is discharged 

from the EXH port. Contamination on the secondary piping and the inside of the load will 

have an adverse effect on performance, etc. Keep the inside of the piping as clean as possible.
When supplying compressed air for the first time after connecting pipes, confirm that no air is 

leaking from any pipe connections.
Tighten pipes with the appropriate torque to prevent air leakage and screw damage. First 

tighten the screw by hand to prevent damage to screw threads, then use a tool.
For the pneumatic source, use cleaned air from which the solid, water and oil contents were 

eliminated sufficiently, using an air dryer, filter and oil mist filter. Recommend selecting a 

filtration precision of 5µm or less.

6

7

8

9

10

11

12

13

a
b
c
d

5

Air filter

(5µm)

Regulator

(Pressure

switch)

Oil/mist filter

Air dryer

Содержание MAER200 Series

Страница 1: ...lat type 5 Cable connector Blank Without S1 Straight 1m S3 Straight 3m L1 Right angle 1m L3 Right angle 3m 6 Port thread Blank Rc thread G G thread NPT NPT thread 7 2 3 4 5 6 7 1 Current DC4 20mA 2 Vo...

Страница 2: ...t be operated by the person who has professional knowledge and practical experience Please confirm product specifications before use Do not use input signal exceeding specifications This product could...

Страница 3: ...ubricator on the supply side of this product the lubricated air might cause malfunction When lubrication of terminal equipment is necessary connect a lubricator on the output side of the equipment and...

Страница 4: ...nction Do not use power voltage exceeding specifications The product could malfunction or catch fire if voltage exceeding the working range is applied Short circuiting the load could result in rupture...

Страница 5: ...e Blue Black 3 Blue 1 Brown 2 White 4 Black Current Voltage type Power supply 24VDC Preset input type Power supply 24VDC Input signal Model 4 20mADC MAER200 1 0 10VDC MAER200 2 0 5VDC MAER200 3 Preset...

Страница 6: ...5mA and then restart the power supply Wiring diagram Monitor output WARNING MAER200 2 MAER200 3 1 Brown 3 Blue 2 White 4 Black 1 Brown 3 Blue 2 White 4 Black Switch output NPN type Switch output PNP t...

Страница 7: ...ressure Max pressure Switch output Preset pressure Gain Sensitivity Zero clear Reset setting Unit setting Display pressure Display unit Click Click Press Click Refer to P 9 Refer to P 10 12 Profession...

Страница 8: ...or not specified it may cause direct burnout or malfunction Please confirm the specifications before use Please contact us when MAER do not operate normally after restarting the power supply 1 Check t...

Страница 9: ...the keys In RUN mode press for more than 2 seconds Locking the key In RUN mode and unlocking press for more than 2 seconds and then press to return RUN mode Operation flow Operation flow 4 00 Loc vnL...

Страница 10: ...ry doing an error ER4 will be indicated You must be return to set F_1 and F_2 F_1 is adjustable in range from 0 to 50 of the rated value DEFAULT VALUE 0 F_2 is adjustable in range from 10 to 100 of th...

Страница 11: ...is not available If you try doing an error Er4 will be indicated You must be return to set P_1 and P_2 Function introduce Window comparator mode Hysteresis mode P_2 P_1 Switch output Output pressure o...

Страница 12: ...pressure range One of the preset pressures P_1 through P_4 is selected by the ON OFF combination of S1 and S2 Function introduce Preset pressure and switch Preset pressure P_1 P_2 P_3 P_4 S1 OFF ON OF...

Страница 13: ...se refer to the following instructions to operate Function introduce Save setting and return to RUN mode Press key to switch the setting item Press key for 2 seconds or more Unlocking key Gn 5b 0 rSt...

Страница 14: ...f Gain 1 2 3 7 8 9 14 15 16 Function introduce Sensitivity High Low Setting of Sensitivity 1 2 5 6 7 14 15 16 Change the sensitivity Sb of the MAER for pressure fluctuation Caution Normal operation do...

Страница 15: ...ng the outlet pressure to atmosphere pressure The adjustable range of the Zero clear function is 5 F S When more than this range ER5 is displayed Please change the outlet pressure and return the setti...

Страница 16: ...ng refer to page 10 Caution The pressure unit is set according to the order specification before leaving the factory If you operate the function to change unit the product will be inconsistent with th...