13
Detail setting mode
Operation flow
After Unlocking, enter the Detail setting mode to adjust the parameters.
Detail setting mode: Gain, Sensitivity, Reset, Zero clear and Unit setting. Please refer to the
following instructions to operate.
Function introduce
Changing the response of the inner solenoid
valve by changing the gain, and then reaching
to control regulated pressure speed of the
MAER.
Caution: When the gain is changed to more
large, the response become quickly, but there is
a possibility that stability is lost.
Save setting and
return to RUN mode
Press key to switch the setting item.
Press key for 2 seconds or more
Unlocking key
G n
5 b
- 0 -
r S t
u N t
s a u
Gain, please refer to page 14.
Sensitivity, please refer to page 14.
Zero clear, please refer to page 15.
Reset function, please refer to page 15.
Unit setting, please refer to page 16.