74
7-21 UK/Plessey
Read:
Format
Data digits (variable)
2 check digits (optional)
Check digit verification: The UK/Plessey has one or two optional check digits. The check digit 1 and
check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of “
7-10 Code 39
”.
Code ID setting: Refer to Code ID setting of “
7-5 UPC-A
”.
Insertion group selection: Refer to Insertion group selection of “
7-5 UPC-A
”.
Multiple-scan setting
Single-scan setting
Option barcode
Option Alpha. entry
Read
Disable
00*
*
Enable
01
Check digit verification
Disable
00
Enable
01*
*
Check digit transmission
Disable
00*
*
Enable
01
Max. code length
00-99
00-99
00*
*
Min. code length
00-99
00-99
01*
*
Code ID setting
00-FF
1
6
(ASCII)
00-FF
16
<U>*
*
Insert group selection
00-66
00-66
00*
*