Sterylis VS Manual
| 26
pressing the yellow START button longer. If the code is incorrectly entered, the code XXXX or HHHH will be displayed and a
short beep will occur. In this case, the code must be re-entered.
You can interfere with the following counters:
Parameter code
Description
d102
UV-C lamp service interval timer [s]
d105
Fan service interval timer [s]
d108
Service interval timer for the 1. ozone generator bank [s]
d111
Service interval timer for the 2. ozone generator bank [s]
d114
Ozone sensor service interval timer [s]
d117
Ozone sensor life timer [s]
d120
Air filter interval timer [s]
d201
Active electricity consumption meter [kWh]
The individual parameters are changed using the + and - buttons in the O
3
STERILIZATION section. The code of the
selected parameter is displayed in the O
3
STERILIZATION section. The current value of the selected parameter is displayed
in the O
3
CONCENTRATION section.
To reset the selected counter, press and hold the PROG.SET button. The reset will be
confirmed by a short beep and all displays will flash.
6.7.1 Electricity consumption counting
The device is equipped with a function of counting the total amount of electricity consumed. The energy is measured in all
operating modes, including standby and sleep mode. The value of the electricity consumed is previewed using the d201
meter.
6.8 Other functionality of the device
Other remaining functionality of the device is described in subsections 6.8.1, 6.8.2 and 6.8.3. They include: AUTO-TEST,
OZONE-SENSOR-TEST, PRE-TEST, SET-FACTORY- SETTINGS, SET-TIME and OZONE-MONITOR functions.
To access the above mentioned functions, press and hold the SET button in the OZONING TIME section of the device
standby mode. Then enter the appropriate code to move to the above mentioned functions.
Entering the access code:
The 4-digit code entered is shown on the display under O
3
STERILIZATION. The + and - buttons change the value by 1
active digit. An active number is the one that flashes at a high frequency, inactive numbers light up constantly. The
PROG.SET button changes the active digit to the next one on the right. After entering the correct code, confirm it by
pressing the yellow START button longer. If the code is incorrectly entered, the code XXXX or HHHH will be displayed and a
short beep will occur. In this case, the code must be re-entered.
The available functions are under the following codes:
Parameter code
Description
t200
AUTO-TEST function
t201
OZONE-SENSOR-TEST function (ozone sensor test)
t202
SET-FACTORY-SETTINGS function (resetting to factory settings)
t204
SET-TIME function (setting the current time)
t205
OZONE-MONITOR function
PRE-TEST function is started automatically when the selected operating mode is activated.