AiRanger SPL
PL-573
Technical Refer
e
nce
When the dust settles (and the echo is regained) the reported level advances toward
the actual level. When the reported level reaches 25.55 m (5% of Span less than the
high high alarm trip point), the high high alarm goes off, restarting the infeed and
filling the vessel to 27.00 m.
Material Volume
To perform a volume conversion for the preceding example, we'll assume:
•
the vessel is cylindrically shaped with a flat bottom.
•
the vessel volume for Empty to 29.01 m (Span) is 1457 m
3
.
Volume Parameter Settings
Number
Description
Instructions
P050
Tank Shape
Enter "1" for
vertical cylinder with flat bottom
.
P051
Max Volume
Enter "1457" for
1457 m
3
.
Now in the RUN mode the Reading represents material volume in m