Tr
oubleshootin
g
Troubleshooting Guide
Symptom
Cause
Action
Display blank, Transmit
Neon not flashing,
transducer not pulsing
No power
Check Power supply, wiring, and
voltage switch.
No response to programmer.
Obstructed infrared interface,
or defective programmer
Clean enclosure “docking bay” and
programmer magnet slot.
Displays “Short” and “tb:(#)”.
Short circuited transducer
cable or defective transducer.
Repair or replace as necessary.
Displays “Open” and “tb:(#)”.
Transducer not connected
Connect transducer, or remove from
service (P001=0).
Open circuited transducer
cable, or defective
transducer.
Repair or replace as necessary
Displays “Error” and “tb:(#)”.
Transducer connected wrong
Reverse BLK and WHT wires
Wrong transducer (P004)
Enter correct value
Displays “LOE”.
Weak or non-existent echo.
Relocate and/or re-aim transducer at
material level or object.
Proceed to Measurement Difficulties.
Displays “EEEE”.
Reading too high.
Select larger Units (P005), or lower
Convert Reading (P061).
Reading fluctuates while
material level is still, (or vice
versa).
Incorrect measurement
stabilization.
Alter measurement Response (P003)
accordingly.
See Technical Reference /
Measurement Response.
Reading is fixed, regardless
of the actual material level.
Transducer beam obstructed,
standpipe too narrow, or
transducer mounting
resonant.
Relocate and/or re-aim transducer at
material level or object
Proceed to Measurement Difficulties.
Material level reported is
always “off” by the same
amount.
Incorrect Empty (zero)
reference.
See Empty (P006), Reading Offset
(P063), Offset Calibration (P650), and
Offset Correction (P652).
Measurement accuracy
improves as level nears
transducer.
Incorrect Sound Velocity used
for distance calculation.
use an ultrasonic/temperature
transducer or a TS-3 temperature
sensor.
See Technical Reference Sound
Velocity.
Reading is erratic, with little
or no relation to material
level.
True echo too weak or wrong
echo being processed.
Relocate and/or re-aim transducer at
material level or object
Proceed to Measurement Difficulties.
Содержание AiRanger SPL PL-573
Страница 1: ...AIRANGER SPL Instruction Manual PL 573 March 2001 IRANGER SPL 33455730 Rev 1 2 ...
Страница 8: ...Page 8 AiRanger SPL PL 573 Specifications ...
Страница 24: ...Page 24 AiRanger SPL PL 573 Installation ...
Страница 86: ...Page 86 AiRanger SPL PL 573 Enhancement Param ...
Страница 102: ...Page 102 AiRanger SPL PL 573 Maintenance ...
Страница 108: ...Page 108 AiRanger SPL PL 573 Troubleshooting ...