Page 78
AiRanger SPL
PL-573
Enhancement Pa
ra
m.
Alternatively, if TVT Type is set for "TVT SLOPES" (P830 = 6), this value is preset to
2000.
Use this feature to adjust the slope declination, as required.
Values:
0 to 9999
P840
Short Shot Number
Enter the number of short shots to be fired (and results averaged) per transmit pulse.
Values:
0 to 100
P841
Long Shot Number
Enter the number of long shots to be fired (and results averaged) per transmit pulse.
This value is automatically altered by Measurement Response (P003).
(See Technical Reference / Measurement Response).
Values:
0 to 200
P842
Short Shot Frequency
Use this feature to adjust the short shot transmit pulse frequency (in kHz).
This feature is automatically altered when Transducer (P004) is altered.
Values:
10.00 to 60.00
P843
Long Shot Frequency
Use this feature to adjust the long shot transmit pulse frequency (in kHz).
This feature is automatically altered when Transducer (P004) is altered.
Values:
10.00 to 60.00
P844
Short Shot Width
Use this feature to adjust the width (in ms) of the short shot transmit pulse.
This feature is automatically adjusted by Transducer (P004).
Values:
0.000 to 5.000
Содержание AiRanger SPL PL-573
Страница 1: ...AIRANGER SPL Instruction Manual PL 573 March 2001 IRANGER SPL 33455730 Rev 1 2 ...
Страница 8: ...Page 8 AiRanger SPL PL 573 Specifications ...
Страница 24: ...Page 24 AiRanger SPL PL 573 Installation ...
Страница 86: ...Page 86 AiRanger SPL PL 573 Enhancement Param ...
Страница 102: ...Page 102 AiRanger SPL PL 573 Maintenance ...
Страница 108: ...Page 108 AiRanger SPL PL 573 Troubleshooting ...