![Milltronics Accumass BW100 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/milltronics/accumass-bw100/accumass-bw100_instruction-manual_1796978082.webp)
MAINTENANCE
The BW100 requires no maintenance.
The external surface of the enclosure may be cleaned using a vacuum cleaner
and a clean dry paint brush. The display window should be cleaned with a moist
non-abrasive cloth.
It is a good idea to check the associated load sensing device, according to its
instruction manual.
SOFTWARE UPDATES
The software can be updated from a floppy disk by use of a PC (IBM Compatible) with
Milltronics Dolphin software. It is recommended that a reset (P999) is done after the
software update followed by zero and span calibrations.
Direct zero entry (P367) and direct span entry (P368) will suffice in lieu of dynamic
zero and span calibrations. Therefore, zero and span counts should be recorded prior
to doing the software update.
APPENDICES
PL-531
82
Содержание Accumass BW100
Страница 1: ...Accumass BW100 May 1997 Instruction Manual PL 531 33455310 Rev 1 5...
Страница 20: ...INSTALLATION PL 531 20...
Страница 34: ...START UP PL 531 34...
Страница 48: ...RECALIBRATION PL 531 48...
Страница 56: ...OPERATION PL 531 56...
Страница 76: ...PARAMETER DESC PL 531 76...