Example :
A non-linearity with respect to the ideal response exists in a belt scale application
with design rate of 200 t/h. It is decided to do material tests at 25, 50 and 75% of the
design rate. After performing a zero and a span calibration at 100% of the design
rate, followed by material tests and manual span adjust, three material tests were
performed at 50, 100 and 150 t/h, as indicated by the BW100. The following data
was tabulated. (This example is exaggerated for emphasis).
The material tests should be run at same belt speed, representative of normal
operation; in this case 1.2 m/s. For each rate, record the corresponding load value by
scrolling to the BW100 load display during running conditions or by calculation.
load = rate
speed
*calculation example: % compensation =
4.2 - 4.9 x 100
4.9
= - 14.3
97/07/07
BW100 load
material test
BW100 total
compensation*
kg/m
tonnes
tonnes
%
11.6
4.2
4.9
-14.3
23.2
8.4
7.6
10.5
34.7
12.6
13.7
- 8.0
load - kg / m
actual weight per material test
totalized weight by BW100
belt scale response
linearized BW100 response
% compensation
span (100%)
weight =
tonnes
RECALIBRATION
PL-531
46
Содержание Accumass BW100
Страница 1: ...Accumass BW100 May 1997 Instruction Manual PL 531 33455310 Rev 1 5...
Страница 20: ...INSTALLATION PL 531 20...
Страница 34: ...START UP PL 531 34...
Страница 48: ...RECALIBRATION PL 531 48...
Страница 56: ...OPERATION PL 531 56...
Страница 76: ...PARAMETER DESC PL 531 76...