START UP
Program P005 - P017
refer to Maneuvering for
parameter selection
and changing values.
*
from design data
sheet, if provided
▲
for constant speed
applications, TB1 - 5/6
jumpered, value is
locked at 100.
Test load value should be less than design load (P952). If not, contact Milltronics or
their agent.
examples are typical
98/03/10
program mode P005, units
e.g. 1, t/h
P014, design speed
*
e.g. 0.5 m/s
P015, speed constant
*
▲
e.g. 100.3 pulse / m
P016, belt length
e.g. 65.72 m
P017, test load
*
e.g. 55.56 Kg / m
P011, design rate
*
e.g. 200 t/h
ST
AR
T UP
PL-531
29