P018
speed constant adjust
This parameter allows adjustment to the speed constant (P015).
Initially, this parameter displays the dynamic speed of the belt.
If the displayed speed is not equal to the actual speed, enter
the actual belt speed.
For speed sensor applications, the value of P015 is
automatically adjusted.
For constant speed (TB1 5/6 jumper) the value of P014
is automatically adjusted.
P019
manual span adjust
This parameter allows adjustment to the span calibration.
The adjustment value is generally determined by performing
material tests. Refer to Recalibration\Material Tests.
enter the calculated adjustment
P022
minimum speed frequency
Sets the minimum frequency that the speed sensor can reliably read.
Signals at low frequencies are erratic, adversely affecting the performance
of the weighing system.
entry: 1 = 1 Hz
2 = 2 Hz
note:at 1 Hz, it takes 1 sec before defaulting to 0 speed
at 2 Hz, it takes 0.5 sec before defaulting to 0 speed