OM-267043 Page 24
SECTION 7
−
MAINTENANCE & TROUBLESHOOTING
7-1. Routine Maintenance
.
Maintain more often
during severe conditions.
!
Disconnect power
before maintaining.
n
= Check
Z
= Change
~
= Clean
l
= Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
l
Damaged Or Unreadable Labels
l
Damaged Gas Hose
n
l
Cracked Cables And Cords
Every
6
Months
n
~
Drive Rolls
~
Blow Out Or Vacuum Inside
7-2. Overload Protection And Thermostat Protection
Ref. 257 794-B
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1
Supplementary Protector CB1
CB1 protects wire feeder from over-
load. Correct problem and reset
CB1.
Close and latch door.
Thermostat Protection
Unit has internal thermostat protec-
tion and will not feed wire if over-
heating occurs (see Section 7-4).
Internal Side View
CB1
1