OM-267043 Page 13
SECTION 5
−
INSTALLATION
5-1. Equipment Connection Diagram
258 966-A / Ref. 257 819-B
3
5
6
10
2
8
9
1
4
!
Turn Off wire feeder and
welding power source.
!
Do not move or operate
equipment where it could tip.
1
Welding Power Source
2
Gas Hose
3
Weld Cable To Feeder
4
Work Cable To Workpiece
Weld cable and work cable connec-
tions to power source (DCEN/DCEP)
are dependant on wire type.
Power source is configured for
DCEP. To run DCEN manually swap
cables.
.
Since feeder is not polarity sensi-
tive, there is no need for an elec-
trode polarity switch.
5
Workpiece
6
Voltage Sensing Clamp
Connect voltage sensing clamp to
workpiece.
7
Gun
8
Gun Trigger Receptacle
9
Wire Feeder
10 Gas Cylinder
Use of shielding gas is dependant on
wire type.
.
Shielding gas pressure not to ex-
ceed 100 psi (689 kPa).
7
5-2. WCC (Weld Cable Control) Applications
.
To take advantage of the WCC features, the FieldPro
t
Feeder must be used with a PipeWorx 350 FieldPro
t
power source.
5-3. Associating Wire Feeder To PipeWorx 350 FieldPro
t
1
Connect feeder to PipeWorx 350 FieldPro
t
.
2
Do not strike an arc.
3
Feeder will display dashed lines and CCV until connected.
4
Once connected the feeder will display voltage.
5
Use voltage control on feeder to adjust weld voltage.
6
The voltmeter will alternate between preset voltage and open circuit voltage while idle or weld voltage at the wire feeder while welding.
.
See Section 5-4 for detailed equipment setup.
Содержание FieldPro Feeder CE
Страница 4: ......
Страница 6: ......
Страница 35: ...OM 267043 Page 29 SECTION 8 ELECTRICAL DIAGRAM 257 274 C Figure 8 1 Circuit Diagram For Wire Feeder...