Page 3-1
Chapter 3: Changing Heating Systems
|
Section 3.1: Changing from Hot Air to Hot Wedge
Chapter 3: Changing Heating Systems
Section 3.1: Changing from Hot
Air to Hot Wedge
1.
Turn the Heat and Power Switch to the off
position to activate the cool down cycle and
wait for the machine to shut down.
2.
Once the cool down cycle is complete and
the machine has shut down the Main Power
Supply must be disconnected. To do this turn
off the Circuit Breaker to the off position.
(Figure3.1)
3.
The Main Air Supply must also be
disconnected and depressurized. First,
disconnect the Shop Air Supply by turning the
ball valve to the off position. Second, release
the quick connect fitting on the end of the
air line which will allow you to remove it.
Third, bleed off the remaining air in the
system by slowly turning the ball valve to the
on position. Once all the remaining air has
escaped and the air cylinders are relaxed
turn the ball valve back to the off position.
(Figure3.2)
4.
Once the machine has sufficiently cooled
down and the Main Power an Air Supply have
been disconnected remove the Fabric Guide
from the machine. This will help clear
obstructions while changing the Heating
System.
5.
The Front Locking Bolt must be loosened
before changing the heating system.Use a 3/
16” Allen Wrench to loosen the Front Locking
Bolt.
(Figure3.3)
6.
Disconnect the green airline that supplies the
Swing Solenoid on the Hot Air Assembly by
pushing in on the white plug at the end of
the air fitting and pulling out the airline.
(Figure3.4)
(Figure3.5)
Figure 3.1:
Figure 3.2:
Figure 3.3:
Figure 3.4:
Figure 3.5:
Содержание T-100