Custom Features
MIKROTRON GmbH
11
‐
6
InfoFieldFrameCounterEnable
This feature enables/disables the Frame Counter that can be added
into the info field in the image. If this option is set a frame counter
will be superimposed upon each captured frame or ROI.
The frame counter occupies 4 pixels in the upper left corner of each
frame starting with pixel number 0. After each activation, the counter
starts with 0. When reaching the maximal value or after each acquisi
‐
tion start command it will restart with 0
.
Access
read / write
Type
boolean
In
ON
OFF
info field is enabled (1)
info field is disabled (0)
Out
pixel 0
frame counter LSB part (counter bits 7
.
..0). The val
‐
ues of pixel 0 and 1 are used to build a consecutive
running bit frame counter in little
‐
endian notation.
If the 24 bit counter overruns
,
it restarts with 0.
pixel 1
frame counter, bits 15 … 8
pixel 2
frame counter, bits 16 … 23
pixel 3
ROI number
For cameras with the Multi
‐
ROI fea
‐
ture the frame counter is inserted into each ROI.
This starts with 1 for ROI 1. Because a set of ROIs
always belongs to one frame the frame counter in
each ROI is the same. For cameras without the
Multi
‐
ROI feature or if only one ROI is defined
,
this
value is always 1.
Remark
In 10 bit mode the bits 1 … 0 in each pixel will be set to 0;
guru feature
Содержание EoSens CAMMC1186
Страница 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Страница 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Страница 87: ...APPENDIX A Technical Data...
Страница 89: ...APPENDIX B Spectral Response...
Страница 91: ...APPENDIX C Bayer Pattern...
Страница 94: ...APPENDIX D Camera Dimensions...
Страница 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...
Страница 96: ...Camera Dimensions MIKROTRON GmbH D 3 Side Views There are three side views available Side View without adapter...