Bootstrap
MIKROTRON GmbH
6
‐
11
ControlPacketSizeMax
This register provides the maximum control packet size the host can
read from the device or write to the device. The size is defined in
Bytes and will be a multiple of 4 Bytes. The defined size is that of the
entire packet, not only the payload.
StreamPacketSizeMax
This register holds the maximum stream packet size the host can
accept. The size is defined in Bytes and will be a multiple of 4 Bytes.
The defined size is that of the entire packet, not only the payload.
Access
read
Type
unsigned integer
In
—
Out
control packet size in multiples of 4 Bytes
Remark
the control packet size is at least 128 Bytes
Access
read / write
Type
unsigned integer
In
stream packet data size in multiples of 4 Bytes
Out
stream packet data size in multiples of 4 Bytes
Remark
The device can use any packet size it wants to up to this size.
A connection reset sets the value to 0x00000000.