Bootstrap
MIKROTRON GmbH
6
‐
12
ConnectionConfig
This register holds a valid combination of the device link speed and
the number of active down connections. Writing into this register sets
the connection speeds on the specified connections.
ConnectionConfigDefault
This register provides the value of the ConnectionConfig register that
allows the Device to operate in default mode. This feature is used to
start the camera with the default configuration that is stored in the
custom profiles.
Access
read / write
Type
enumeration
connection configuration example (read the electronically read
‐
able manual for further information):
CONNECTION4SPEED3125
four connections of 3.125 Gbps per
connection (default)
CONNECTION4SPEED5000
four connections of 5.000 Gbps per
connection
CONNECTION4SPEED6250
four connections of 6.250 Gbps per
connection
Out
connection configuration
Access
read
Type
unsigned integer
In
—
Out
0x00000000
Remark
Содержание EoSens CAMMC1186
Страница 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Страница 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Страница 87: ...APPENDIX A Technical Data...
Страница 89: ...APPENDIX B Spectral Response...
Страница 91: ...APPENDIX C Bayer Pattern...
Страница 94: ...APPENDIX D Camera Dimensions...
Страница 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...
Страница 96: ...Camera Dimensions MIKROTRON GmbH D 3 Side Views There are three side views available Side View without adapter...