Faults and error messages
Error messages
Fault
Possible cause
Troubleshooting
Responsi-
bility
"Er00" displayed
Door open during process
Close door (“Press”)
Poss. readjust door locking
User
Service de-
partment
“Er01" displayed
Excessive temperature
Replace the thermocouple.
Service de-
partment
"Er02" displayed
Broken sensor, measuring
circuit
Retighten the thermocouple con-
nections.
"Er03" displayed
Broken sensor
Replace the thermocouple.
“Er04" displayed
Thermocouple reverse polar-
ity
Connect thermocouple correctly
+ orange line
- white line
"Er05" displayed
Thermocouple short-circuit-
ed or heater defective
Check the heater/thermocouple
and have it/them replaced if nec-
essary.
"Er06" displayed
Defective electronic system
Check the electronic system and
have it replaced if necessary.
"Er09" displayed
Power failure
If there is a brief power failure
during a heating-up or cool-
ing-down phase and the tempera-
ture is below 1000 °C, the process
will be continued once power has
been restored. If the power failure
lasts longer than 10 seconds and
the temperature is above 1000 °C,
the process will be stopped and
the display will flash.
The
Start/
Stop
but-
ton must be
pressed to
acknowledge
error Er09.
Содержание TABEO Series