Connecting the argon supply
$
Danger
Danger due to escaping gas!
Potential risk of explosion or fire as well as suffocation.
h
During all work on the Tabeo-2/M/Metal-120, the argon and voltage
supply must be shut off (pull out mains plug) and the gas bottle must
be closed.
h
When working with argon, observe the national safety regulations
TRGS526 (Chapter 5.2.11 “Compressed gas bottles and fittings”).
1.
Close the connecting hose (included in the delivery) at the sintering
oven (A) and the argon supply (gas bottle).
Abb. 2: Argon connection Tabeo Metal (illustrative example)
2.
Set the outlet pressure of the gas bottle to 6-7 bar (optimal pressure!).
Maximum pressure: 10 bar!
Notice
If the outlet pressure of the gas bottle is higher or lower than 6-7 bar, too
much/too little argon will enter the sintering dish and the sintering process
will fail!
3.
Check the gas lines and connected couplings for leaks and a secure
fit.
Â
In the event of a malfunction the volume of an argon bottle is suffi
-
cient to flood the entire room.
A ventilation in the floor area is recommended (argon is heavier than
air and settles on the floor).
4.
Protect the ducts and shafts against penetration by gas.