Plumbing
The stack is built in accordance with
current standards and must be
connected to a water supply in
accordance with local and national
safety regulations. It can be connected
with out a non-return valve if national
regulations permit
The stack is designed to operate with a
flow pressure of between 100 kPa and
1,000 kPa (14.5 psi to 145 psi). At
higher water pressures it is essential to
fit a reducer valve.
Connection to the water supply should
be carried out by a qualified plumber
and should incorporate a stopcock with
a 3/4" thread. The stopcock should be
fitted by a qualified plumber.
The washer-extractor is supplied as
standard with two hoses, for connection
to a hot and cold water supply.
The cold water inlet hose (blue
stripes) must be connected to the
on-site cold water supply via a 3/4"
threaded union. It is is
not
suitable
for connection to a hot water supply.
,
The connection point is subject
to water pressure. Turn on the
stopcock slowly and check for
leaks. Correct the position of the
washer and union if appropriate.
Maintenance and care
Only use a genuine Miele hose should
you ever need a replacement. Miele
hoses are tested to withstand pressure
of at least 7,000 kPa (1,015 psi).
In order to protect the water inlet
valve, the two dirt filters - one in the
open end of the inlet hose, one at
the inlet point in the
washer-extractor must not be
removed.
Extension hose
Longer hoses 8' 2 7/16" or 13' 1 1/2"
(2.5 or 4 m) in length are available from
Miele as optional accessories.