Risk of damage!
In environments with high humidity
condensation can build up on the
exterior of the appliance. This
condensate can cause corrosion of
the appliance walls.
For prevention, it is advisable to
install the appliance with sufficient
ventilation in a dry and/or air
conditioned room.
After installation please ensure that
the appliance doors close properly,
the ventilation gaps are not covered
and that the appliance has been
installed in accordance with these
installation instructions.
Climate range
The appliance is designed for use within
a certain climate range (ambient
temperatures) and should not be used
outside this range. The climate range of
the appliance is stated on the data plate
inside the appliance.
Climate range
Ambient room
temperature
SN
+10 to +32 °C
N
+16 to +32 °C
ST
+16 to +38 °C
T
+16 to +43 °C
Operating in a room which is too cold
will result in the compressor switching
off for too long, causing the internal
temperature in the appliance to rise with
the risk of food deteriorating and going
off.
Ventilation
If the required ventilation gaps
are not adhered to, the compressor
will switch on more often and run for
longer.
This will result in increased energy
consumption and a higher operating
temperature of the compressor. This,
in turn, may cause damage to the
compressor.
It is essential to observe the required
ventilation gaps.
Air at the back of the appliance gets
warm. The appliance housing unit must
therefore be constructed to allow
sufficient space for ventilation (see
“Building-in dimensions”).
– Air intake
occurs via the plinth at
the bottom of the appliance and the
air escapes at the top
at the back
of the housing unit.
– A ventilation gap of at least 40 mm
depth must be allowed for behind the
appliance for air to circulate.