Technical Information
55
G 600/G 800
5.12
Lock/Handle Assembly Removal
Caution!
Ensure that power is disconnected at the wall outlet by shutting off the appropriate
circuit breaker.
1. Remove the outer door panel. Refer to Section 5.10.
2. Remove the control panel. Refer to Section 5.47.
3. Open the door and remove the screw (Figure 5-15, Item 3).
Note:
A sealing ring is located under the countersunk screw. This sealing ring must be re-
installed during reassembly.
4. Remove the lock and cover.
5. Disconnect the plug contacts from the switch.
6. Dismantle the lock and cover.
7. When re-installing, ensure that the two lugs on the switch engage in the holes
provided.
Figure 5-15:
Lock Removal
5.13
Door Hinge Removal
1. Remove the side panel. See Section 5.3.
2. Remove the outer door panel. See Section 5.10.
3. Remove the tensioning spring. See Section 5.4.
Warning!
Ensure that the door is held in position and supported while opening it.
4. Open the door. Remove the raised screws (Figure 5-16, Item 1).
5. Close the door. Remove the screw (Figure 5-16, Item 2).
6. Remove the hinge bolt retainer (Figure 5-16, Item 3).
7. Remove the hinge bolt (Figure 5-16, Item 4).
8. Remove the hinge.
Note:
When reassembling, lightly coat all moving parts with acid-free grease.