Technical Information
115
G 600/G 800
Program
Function
Options
Program light status
Rinse & Hold
Extended drying
1
Off Flashing
On Lit
Pots & Pans
EGS
On Flashing
Off Lit
Table 6-51:
G 892, G 832 Service Mode 2 Functions
1
Can only be set if “+14 min” is selected in programming mode. See Section 6.8.9.1.2.
6.8.10
G 694, G 894
Programming Flow Chart
Enter
Programming Mode
To access:
Water hardness settings
Extended drying fan time (+14 minutes)
Enter
Service Mode 1
To access:
Manual step mode
Component test program
Enter
Service Mode 2
To access:
Error messages
Program index
Increased water temperature selection
Water softener (with/without)
Interim rinses
Extended water intake
Extended drying fan time (+ 45 minutes)
EGS
Table 6-52:
G 694, G 894 Programming Flow Chart
6.8.10.1 Programming
Mode
1. To access the
programming mode
,
close the door and turn the dishwasher on.
The
Start/Stop
light
must
be blinking. If the
Start/Stop
light is
not
blinking, press
and hold the
Start/Stop
button for at least 3 seconds to exit the cycle. The
Start/Stop
light should now be blinking.
2. Turn the dishwasher off.
3. Press and hold the
Top solo
and
Start/Stop
buttons while turning the
dishwasher on. Successful accessing of the
programming mode
is indicated by
a blinking
Salt
light.
4. The display will show the current water hardness setting. The
“A”
indicates
Aqua
and the numbers indicate the hardness setting.
Note:
If the display is blank, the appliance has been programmed for “without softener”.
See
Service Mode 2
(Section 6.8.10.3) to turn the water softener
on or off.