Technical Information
83
G 600/G 800
Selector switch
position (o’clock)
Function
Options
Status of Start light
1 to 8
Water hardness
(see Section 6.8.1.1.1) Light 1 to 8 on
1
10 Heated
drying
2
On
3
Off
Off
On
11 Water
intake
time
2
70 seconds
3
100 seconds
Off = 70 sec
On = 100 sec
Table 6-2:
G 841, G 841 Plus, G 842 Programming Functions
1
If no lights light up, the dishwasher is programmed for “without water softener”. To change to
“with water softener”, follow the steps for Service Mode 2 (Section 6.8.1.3).
2
G 841 and G 842 only
3
Factory setting
6.8.1.1.1
Setting the Water Hardness
1. Measure the water hardness in grains per gallon (gpg).
2. Access
Programming Mode
.
3. Using Table 6-3 below, turn the program selector switch to the corresponding water
hardness position, e.g., for water hardness = 10 gpg, turn the program selector switch to
the 3 o’clock position.
4.
To save:
Press the
Start
button (
Start
light lights up), turn the program selector switch to
Stop
and turn the dishwasher off.
Water hardness in gpg
Selector switch position (o’clock)
1-4 1
5-7 2
8-10 3
11-14 4
15-17 5
18-21 6
22-35 7
36-70 8
Table 6-3:
G 841, G 841 Plus, G 842 Water Hardness Chart
6.8.1.1.2
Checking the Water Hardness Level
1. Access
Programming Mode
.
2. Turn the program selector switch slowly through the first 8 clock positions.
3. The
Start
light will light up when the programmed water hardness setting is reached.
4. Match the lit light to the water hardness chart in Table 6-3.
5. Turn the dishwasher off.
6.8.1.2
Service Mode 1
1. To access the
Manual Step Mode
, close the door and turn the program selector
switch to
Stop
. Turn the dishwasher off.
2. Press and hold the
Start
button while turning the dishwasher on. Hold the
Start
button for at least 2 seconds. A lit
Intake/Drain
light indicates successful
accessing of
Service Mode 1.
3. Select a program and press the
Start
button.
4. Pressing the
Start
button repeatedly will allow the technician to advance through
the program manually. If the
Start
button is not pressed, the program steps are
carried out automatically, in their normal order.