6

 

Registering Your MDX-Series Tester

Before using your tester, we recommend that you register it online to activate 

your warranty. Registration will also make it faster and easier for you to obtain 

technical support and service.
To register, log on at www.midtronics.com/warranty.html and have your serial 

number ready. The number is at the bottom of the label on the back of the 

tester.
If  your  tester  needs  repair,  call 

Midtronics  Customer  Service  at 

800.776.1995.  Servicing  the  tester 

yourself  may  void  your  warranty.   

Refer to “Patents, Limited Warranty, 

Service”  on  the  back  cover  for 

additional warranty information.

Display and Keypad

When you first connect the MDX-650 to a battery, it functions as a voltmeter 

until you press the 

ENTER

 button.

IMPORTANT:

 If you connect the tester to a voltage source greater than 30 Vdc, 

you may damage the tester’s circuitry.

The  menu-driven  display  will  then  guide  you  step  by  step  through  the  test 

process. Use the keypad buttons to scroll to and select options in the menu.
To turn off the tester when not connected to the battery, briefly press and hold 

the 

MENU

 button.

Serial Number Label

Serial 

number

www.midtronics.com

MDX-650P

Battery Conductance &
System Analyzer

Содержание MDX-650 MILITARY

Страница 1: ...ies and 12 24 volt starting charging systems INSTRUCTION MANUAL INNOVATION TECHNOLOGY QUALITY WORLDWIDE INNOVATION TECHNOLOGY QUALITY WORLDWIDE MDX 650P Battery Conductance System Analyzer Battery Con...

Страница 2: ...Blank page...

Страница 3: ...NTER Button 7 BACK PRINT Button 7 MENU Button 7 Options Menu 8 Procedure 8 Preparations Before the Test 9 Connecting the Tester 9 Battery Test 10 Battery Test Results 11 Starter System Test 13 Starter...

Страница 4: ...ssages 16 Error Messages 17 Maintenance Troubleshooting 18 Changing The Cable Assembly 18 Troubleshooting the Display 19 Replacing the Battery 19 www midtronics com MDX 650P Battery Conductance System...

Страница 5: ...or other reproduc tive harm Wash hands after handling Capabilities The MDX 650 Battery Conductance and Electrical System Analyzer tests 6 12 volt regular flooded AGM flat plate AGM spiral and gel batt...

Страница 6: ...d your warranty Refer to Patents Limited Warranty Service on the back cover for additional warranty information Display and Keypad When you first connect the MDX 650 to a battery it functions as a vol...

Страница 7: ...one space when creating custom headers You can also use this button to printout test results with the IR printer 4 MENU Button Use the MENU button to access the Main Menu options of the tester For inf...

Страница 8: ...battery and system test by results Contrast Adjust the contrast setting of the tester display Default 10 Temperature Units Select the temperature units Degrees F or Degrees C Default Degrees F Voltme...

Страница 9: ...n the vehicle make sure all accessory loads are off the key is not in the ignition and the doors are closed Connecting the Tester t POOFDU UIF SFE DMBNQ UP UIF QPTJUJWF UFSNJOBM BOE UIF CMBDL DMBNQ UP...

Страница 10: ...PMM UP 501 1045 4 1045 PS 6 1 45 35 1045 XIFSF BQQMJDBCMF 11 5 0 4DSPMM UP BOE TFMFDU 650 05 7 0503 3 8 3 3061 PS 0 3 4 55 3 5 1 Scroll to and select REGULAR 00 AGM FLAT PLATE AGM SPIRAL or GEL where...

Страница 11: ...appears again after you fully charge the battery replace the battery REPLACE BATTERY Replace the battery and retest A REPLACE BATTERY result may also mean a poor connection between the battery cables...

Страница 12: ...display alternates between the test results and the message PRESS 8 03 45 35 3 5 45 See Maintenance Troubleshooting in this manual for more information about the printer IMPORTANT The MDX 650 retains...

Страница 13: ...the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY The starter voltage is low and the battery is discharged Fully charge the battery an...

Страница 14: ...stem Test Results Decision Interpretation NO PROBLEMS System is showing normal output from the alternator NO OUTPUT No alternator output detected Check all connections to and from the alternator espec...

Страница 15: ...sure there are no loose connections and the ground connection is normal If there are no connection problems replace the regulator Most alternators have a built in regulator that requires replacing the...

Страница 16: ...ne or both clamps are not making proper contact with the battery terminals ENGINE REV NOT DETECTED PRESS8 WHILE REVVING Tester has not detected an increase in engine rpm REVERSE CONNECTION Clamps are...

Страница 17: ...SOON Internal AA batteries are low and need to be replaced See Maintenance Troubleshooting section NON 12 VOLT SYSTEM DETECTED System being tested is not 12 volts QC DATA MEMORY FULL PRINT RESULTS OR...

Страница 18: ...circled screw 2 Remove the screw 3 Grasp the housing and firmly pull the cable assembly from housing 4 To attach a new cable align the cable and tester housings and push to gether Insert the screw an...

Страница 19: ...l batteries are OPU GVODUJPOJOH 5IF UFTUFS EJTQMBZT 08 5 3 55 3 4 3 1 55 3 4 400 when the internal AA batteries need to be replaced NOTE Setup information will be retained while you change the interna...

Страница 20: ...Midtronics Inc by Johnson Controls Inc and or Motorola Inc Limited Warranty This battery tester is warranted to be free of defects in materials and workmanship for a period of one year from the date...

Отзывы: