background image

 

8

 

Option

Explanation

View/Print

Display the previous test result.  Press the PRINT 

button to print the results.

QC Mode

A quick test to check battery inventory

Export Data

Export the last test result to an IR Reader program. 

(under development)

Perform Test

Begin the Battery Test procedure.

Language Selection

Select a language for the tester.  

(Default: English)

Set Address

Enter the address to display on the top of the printout.

(Limit: 8 lines, 21 characters per line)

Time

Select 24-hour or AM/PM and set the time. (Default: 

AM/PM)

Date

Select the date format as well as set the correct date. 
(Default: 

MM/DD/YYYY)

Counter

Clear or display battery and system test by results.

Contrast

Adjust the contrast setting of the tester display. 

(Default: 10)

Temperature Units

Select the temperature units 

Degrees F or Degrees C  

(Default: Degrees F)

Voltmeter

Automatically test battery voltage when the clamps are 

first connected to the battery terminals. Press 

ENTER

 

to continue testing the battery. Press 

BACK

 to return to 

the menu.  (Default: ON)

Options Menu

Procedure

 1SFTTUIF.&/6CVUUPOUPBDDFTTUIF0QUJPOT.FOV

2.  Use the UP (

p

BOE%08/ 

q

) arrows to move to the line you want to edit.

 1SFTTUIF&/5&3CVUUPOUPNBLFIJHIMJHIUFEMJOFFEJUBCMF

4.  Use the UP (

p

BOE%08/ 

q

) arrows to select the character for that cur-

sor location.

 1SFTTUIF&/5&3CVUUPOUPNPWFUPUIFOFYUMPDBUJPO
 1SFTTUIF.&/6CVUUPOUPSFUVSOUPUIF0QUJPOT.FOV

www.midtronics.com

MDX-650P

Battery Conductance &
System Analyzer

Содержание MDX-650 MILITARY

Страница 1: ...ies and 12 24 volt starting charging systems INSTRUCTION MANUAL INNOVATION TECHNOLOGY QUALITY WORLDWIDE INNOVATION TECHNOLOGY QUALITY WORLDWIDE MDX 650P Battery Conductance System Analyzer Battery Con...

Страница 2: ...Blank page...

Страница 3: ...NTER Button 7 BACK PRINT Button 7 MENU Button 7 Options Menu 8 Procedure 8 Preparations Before the Test 9 Connecting the Tester 9 Battery Test 10 Battery Test Results 11 Starter System Test 13 Starter...

Страница 4: ...ssages 16 Error Messages 17 Maintenance Troubleshooting 18 Changing The Cable Assembly 18 Troubleshooting the Display 19 Replacing the Battery 19 www midtronics com MDX 650P Battery Conductance System...

Страница 5: ...or other reproduc tive harm Wash hands after handling Capabilities The MDX 650 Battery Conductance and Electrical System Analyzer tests 6 12 volt regular flooded AGM flat plate AGM spiral and gel batt...

Страница 6: ...d your warranty Refer to Patents Limited Warranty Service on the back cover for additional warranty information Display and Keypad When you first connect the MDX 650 to a battery it functions as a vol...

Страница 7: ...one space when creating custom headers You can also use this button to printout test results with the IR printer 4 MENU Button Use the MENU button to access the Main Menu options of the tester For inf...

Страница 8: ...battery and system test by results Contrast Adjust the contrast setting of the tester display Default 10 Temperature Units Select the temperature units Degrees F or Degrees C Default Degrees F Voltme...

Страница 9: ...n the vehicle make sure all accessory loads are off the key is not in the ignition and the doors are closed Connecting the Tester t POOFDU UIF SFE DMBNQ UP UIF QPTJUJWF UFSNJOBM BOE UIF CMBDL DMBNQ UP...

Страница 10: ...PMM UP 501 1045 4 1045 PS 6 1 45 35 1045 XIFSF BQQMJDBCMF 11 5 0 4DSPMM UP BOE TFMFDU 650 05 7 0503 3 8 3 3061 PS 0 3 4 55 3 5 1 Scroll to and select REGULAR 00 AGM FLAT PLATE AGM SPIRAL or GEL where...

Страница 11: ...appears again after you fully charge the battery replace the battery REPLACE BATTERY Replace the battery and retest A REPLACE BATTERY result may also mean a poor connection between the battery cables...

Страница 12: ...display alternates between the test results and the message PRESS 8 03 45 35 3 5 45 See Maintenance Troubleshooting in this manual for more information about the printer IMPORTANT The MDX 650 retains...

Страница 13: ...the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY The starter voltage is low and the battery is discharged Fully charge the battery an...

Страница 14: ...stem Test Results Decision Interpretation NO PROBLEMS System is showing normal output from the alternator NO OUTPUT No alternator output detected Check all connections to and from the alternator espec...

Страница 15: ...sure there are no loose connections and the ground connection is normal If there are no connection problems replace the regulator Most alternators have a built in regulator that requires replacing the...

Страница 16: ...ne or both clamps are not making proper contact with the battery terminals ENGINE REV NOT DETECTED PRESS8 WHILE REVVING Tester has not detected an increase in engine rpm REVERSE CONNECTION Clamps are...

Страница 17: ...SOON Internal AA batteries are low and need to be replaced See Maintenance Troubleshooting section NON 12 VOLT SYSTEM DETECTED System being tested is not 12 volts QC DATA MEMORY FULL PRINT RESULTS OR...

Страница 18: ...circled screw 2 Remove the screw 3 Grasp the housing and firmly pull the cable assembly from housing 4 To attach a new cable align the cable and tester housings and push to gether Insert the screw an...

Страница 19: ...l batteries are OPU GVODUJPOJOH 5IF UFTUFS EJTQMBZT 08 5 3 55 3 4 3 1 55 3 4 400 when the internal AA batteries need to be replaced NOTE Setup information will be retained while you change the interna...

Страница 20: ...Midtronics Inc by Johnson Controls Inc and or Motorola Inc Limited Warranty This battery tester is warranted to be free of defects in materials and workmanship for a period of one year from the date...

Отзывы: