background image

www.midtronics.com

Corporate Headquarters

 

Willowbrook, IL USA 
USA Toll Free:   1.800.776.1995
Phone:  

1.630.323.2800

Fax:  

1.630.323.2844

E-Mail: [email protected] 

Canadian Inquiries 

Toll Free:  

1.866.592.8053 

Fax:  

1.630.323.7752 

E-Mail: [email protected]

Midtronics b.v.

European Headquarters

Serving Europe, Africa,the Middle 

&BTUBOE5IF/FUIFSMBOET
1IPOF

 

'BY

E-Mail: [email protected]

Midtronics China Office

 

$IJOB0QFSBUJPOT

 

Shenzhen, China

1IPOF

'BY

E-Mail: [email protected]
Asia/Pacific (excluding China) 
Contact Corporate Headquarters at  

PS

 

E-Mail: [email protected]

167-025A  4/08    2008 Midtronics, Inc. All rights reserved.   

Patents

The  MDX-650  is  made  in  the  U.S.A.  by  MIDTRONICS,  INC.  and  is  protected 
by one or more of the following U.S. Patents: 6,323,650; 6,316,914; 6,304,087; 
6,249,124;  6,163,156;  6,091,245;  6,051,976;  5,831,435;  5,821,756;  5,757,192; 
5,592,093;  5,585,728;  5,572,136;  4,912,416;  4,881,038;  4,825,170;  4,816,768; 
4,322,685;  Canadian  patents:  1,280,164;  1,295,680;  United  Kingdom  patents: 
0,417,173; 0,672,248; German patents: 689 23 281.0-08; 693 25 388.6; 93 21 638.6; 
and other U.S. and Foreign patents issued and pending. This product may utilize 
technology exclusively licensed to Midtronics, Inc. by Johnson Controls, Inc. and/
or Motorola, Inc.

Limited Warranty

This battery tester is warranted to be free of defects in materials and workmanship 
for a period of one year from the date of purchase. Midtronics will, at our option, 
repair the unit or replace the unit with a remanufactured tester. This limited warranty 
applies only to Midtronics battery testers and does not cover any other equipment, 
static  damage,  water  damage,  overvoltage,  dropping  unit  or  damage  resulting 
from extraneous causes including owner misuse. Midtronics is not liable for any 
incidental or consequential damages for breach of this warranty. The warranty is 
void if owner attempts to disassemble the unit or modify the cable assembly.

Service

For  service,  contact  Midtronics  at  800-776-1995  (630-323-2800)  for  a  Return 
Authorization number, and return the unit to Midtronics freight prepaid, Attention: 
RA#.  Midtronics  will  repair  or  replace  the  tester  and  reship,  the  next  scheduled 
business  day  following    receipt,  using  the  same  type  carrier  and  service  as 
received.  If  Midtronics  determines  that  the  failure  was  caused  by  misuse, 
alteration,  accident,  or  abnormal  condition  of  operation  or  handling,  purchaser 
will have the option of purchasing a replacement tester or the unit will be returned 
freight collect. Battery testers beyond the warranty period are subject to the repair 
charges in effect at that time.

Содержание MDX-650 MILITARY

Страница 1: ...ies and 12 24 volt starting charging systems INSTRUCTION MANUAL INNOVATION TECHNOLOGY QUALITY WORLDWIDE INNOVATION TECHNOLOGY QUALITY WORLDWIDE MDX 650P Battery Conductance System Analyzer Battery Con...

Страница 2: ...Blank page...

Страница 3: ...NTER Button 7 BACK PRINT Button 7 MENU Button 7 Options Menu 8 Procedure 8 Preparations Before the Test 9 Connecting the Tester 9 Battery Test 10 Battery Test Results 11 Starter System Test 13 Starter...

Страница 4: ...ssages 16 Error Messages 17 Maintenance Troubleshooting 18 Changing The Cable Assembly 18 Troubleshooting the Display 19 Replacing the Battery 19 www midtronics com MDX 650P Battery Conductance System...

Страница 5: ...or other reproduc tive harm Wash hands after handling Capabilities The MDX 650 Battery Conductance and Electrical System Analyzer tests 6 12 volt regular flooded AGM flat plate AGM spiral and gel batt...

Страница 6: ...d your warranty Refer to Patents Limited Warranty Service on the back cover for additional warranty information Display and Keypad When you first connect the MDX 650 to a battery it functions as a vol...

Страница 7: ...one space when creating custom headers You can also use this button to printout test results with the IR printer 4 MENU Button Use the MENU button to access the Main Menu options of the tester For inf...

Страница 8: ...battery and system test by results Contrast Adjust the contrast setting of the tester display Default 10 Temperature Units Select the temperature units Degrees F or Degrees C Default Degrees F Voltme...

Страница 9: ...n the vehicle make sure all accessory loads are off the key is not in the ignition and the doors are closed Connecting the Tester t POOFDU UIF SFE DMBNQ UP UIF QPTJUJWF UFSNJOBM BOE UIF CMBDL DMBNQ UP...

Страница 10: ...PMM UP 501 1045 4 1045 PS 6 1 45 35 1045 XIFSF BQQMJDBCMF 11 5 0 4DSPMM UP BOE TFMFDU 650 05 7 0503 3 8 3 3061 PS 0 3 4 55 3 5 1 Scroll to and select REGULAR 00 AGM FLAT PLATE AGM SPIRAL or GEL where...

Страница 11: ...appears again after you fully charge the battery replace the battery REPLACE BATTERY Replace the battery and retest A REPLACE BATTERY result may also mean a poor connection between the battery cables...

Страница 12: ...display alternates between the test results and the message PRESS 8 03 45 35 3 5 45 See Maintenance Troubleshooting in this manual for more information about the printer IMPORTANT The MDX 650 retains...

Страница 13: ...the battery is fully charged LOW VOLTAGE The starter voltage is low and the battery is fully charged CHARGE BATTERY The starter voltage is low and the battery is discharged Fully charge the battery an...

Страница 14: ...stem Test Results Decision Interpretation NO PROBLEMS System is showing normal output from the alternator NO OUTPUT No alternator output detected Check all connections to and from the alternator espec...

Страница 15: ...sure there are no loose connections and the ground connection is normal If there are no connection problems replace the regulator Most alternators have a built in regulator that requires replacing the...

Страница 16: ...ne or both clamps are not making proper contact with the battery terminals ENGINE REV NOT DETECTED PRESS8 WHILE REVVING Tester has not detected an increase in engine rpm REVERSE CONNECTION Clamps are...

Страница 17: ...SOON Internal AA batteries are low and need to be replaced See Maintenance Troubleshooting section NON 12 VOLT SYSTEM DETECTED System being tested is not 12 volts QC DATA MEMORY FULL PRINT RESULTS OR...

Страница 18: ...circled screw 2 Remove the screw 3 Grasp the housing and firmly pull the cable assembly from housing 4 To attach a new cable align the cable and tester housings and push to gether Insert the screw an...

Страница 19: ...l batteries are OPU GVODUJPOJOH 5IF UFTUFS EJTQMBZT 08 5 3 55 3 4 3 1 55 3 4 400 when the internal AA batteries need to be replaced NOTE Setup information will be retained while you change the interna...

Страница 20: ...Midtronics Inc by Johnson Controls Inc and or Motorola Inc Limited Warranty This battery tester is warranted to be free of defects in materials and workmanship for a period of one year from the date...

Отзывы: