background image

Midtronics B.V.     Hoofdveste 6 - 8     Houten NL

www.midtronics.com

EXP-1000 HD

Chapter 2: Description 

Data Entry Methods

To perform a particular test or function, the tester will ask for 

diff erent types of information. This means that the methods 

you use to enter information will change depending on 

the type of information requested. The four types of entry 

methods are described below. 
Typically, the soft key below the right half of the screen 

confi rms your choice, although the word above it may vary. In 

a similar fashion, the soft key below the left half of the screen 

cancels your choice or returns you to the previous screen, 

although the word above it may also vary. 

Menu icons

A menu icon is a graphical representation of a function you 
can select. To select an icon, use the 

LEFT

 or 

RIGHT ARROW

 

key to highlight it. Highlighting changes the icon to a white 

picture on a black background. To confi rm your selection, 

press the appropriate soft key.

Option Buttons

Some lists have option buttons before each item. 
To select an item, use the 

UP/DOWN ARROW

 keys to 

move the dot into the button next to the item you want. You 

can also use the alphanumeric keypad to enter the number 

preceding the option button. To confi rm your selection, press 

the appropriate soft key.

Scrolling Lists

Scrolling lists contain items that extend above and below 

the screen or the selection box that contains them. 

To indicate that there are more items, the symbols   appear 

to the right of the fi rst visible or highlighted item on the list. 
To select from this type of list, use the 

UP/DOWN ARROW

 

keys to scroll to the item, or use the keypad to enter your 

choice, and press the appropriate soft key.

Alphanumeric Entries

Even though the tester does not use an alphanumeric keypad 

it is possible to enter alphanumeric  values. When applicable 
the alphanumeric values appear on the display. Use the 

UP/

DOWN or LEFT/RIGHT ARROW

 keys to scroll and confi rm 

this with the > key. To return one or more steps use the < key. 

Содержание EXP-1000 Heavy Duty

Страница 1: ...EXP 1000 Heavy Duty For testing 12 volt Truck and automotive batteries and 12 and 24 volt charging systems INSTRUCTION MANUAL...

Страница 2: ...This page intentionally left blank...

Страница 3: ...ge 11 Deep Scan Test 11 Battery Test Results 12 Battery Test 13 Starter Test 13 Starter System Test Results 13 Chapter 5 System Test 13 5 Minute Discharged Battery Test 14 Alternator Test 14 Alternato...

Страница 4: ...xplosive mix of hydrogen gas and oxygen even when the battery is not in operation Always work in a well ventilated area Wash hands after handling REQUIRED BY CALIFORNIA PROP 65 Battery posts terminals...

Страница 5: ...B 9 connector for future expandability Removing and Inserting the Data Card The analyzer ships with a storage card slot to protect it from dust and debris To remove the data card push briefly on its e...

Страница 6: ...re SELECT BACK and END POWER Key Press the POWER button to turn the analyzer on and off The analyzer also turns on automatically when you connect its test leads to a battery Title Bar The title bar sh...

Страница 7: ...o confirm your selection press the appropriate soft key Option Buttons Some lists have option buttons before each item To select an item use the UP DOWN ARROW keys to move the dot into the button next...

Страница 8: ...tests performed since the tester was first used the totals by decision or allows you to clear the counters An optional IR software and hardware package enables you to transfer test data to a PC Displ...

Страница 9: ...tive and negative post At the start of the test make sure all vehicle accessory loads are off the key is not in the ignition and the doors are closed Connecting the Battery Test Cable CAUTION Do not c...

Страница 10: ...can provide at 0 F 17 8 C 100 to 1700 JIS Japanese Industrial Standard shown on a battery as a combination of numbers and letters 73 numbers from 26A17 to 245H52 DIN A Deutsche Industrie Norm 100 to...

Страница 11: ...weak or that has just been charged may retain enough electrical activity to be detected by the analyzer and will adversely affect the test results A fully charged battery should stabilize quickly afte...

Страница 12: ...liver its specified performance compared with a new battery Good Battery Result Battery Decisions and Recommendations Decision Recommended Action GOOD BATTERY Return the battery to service GOOD RECHAR...

Страница 13: ...key 6 The analyzer displays one of the decisions and the results in a series of screens NOTE In some cases the tester may not detect the vehicle s starting profile It will display the soft key option...

Страница 14: ...RN OFF LOADS AND ENGINE or asked to CHECK IF CLAMP POINTS AWAY FROM THE NEGATIVE BATTERY POST In case of the former turn off vehicle loads blowers interior light radio etc and the engine Press the NEX...

Страница 15: ...ns from the alternator to the battery If the connection is loose or heavily corroded clean or replace the cable and retest HIGH VOLTAGE The voltage output from the alternator to the battery exceeds th...

Страница 16: ...is is so that the chemi cal process is completed Procedure Connect the battery analyser to the battery terminals Note Connect one battery at a time when running this battery test NOTE Parallel connect...

Страница 17: ...ey to move up or down four part numbers at a time Press the NEXT soft key to continue 3 Press an UP or DOWN ARROW key or use the numeric keys to select the BATTERY RATING or in the case of JIS the par...

Страница 18: ...inue 4 Select the RATING UNITS 1 CCA 2 JIS 3 DIN 4 SAE 5 IEC 6 EN Press the NEXT soft key to continue 5 Select the BATTERY RATING Press the UP and DOWN ARROW keys to select the rating In case of a JIS...

Страница 19: ...M mode 2 Press the OK soft key to save your setting Date Date cannot be changed Format Use the UP DOWN ARROWS to select the desired option 1 MM DD YYYY month day year or DD MM YYYY day month year 2 Pr...

Страница 20: ...on screens contain eight lines of text with up to 16 characters on each line Screen 1 1 YOUR SHOP NAME 2 1000 ANY STREET 3 YOUR TOWN STATE 4 YOUR POSTAL CODE Screen 2 5 YOUR COUNTRY 6 YOUR PHONE NUMBE...

Страница 21: ...re using files on an SD card The use of a special formatted card is required for this action FIRMWARE use this option when new software becomes available from Midtronics SAVE CONFIG the tester will st...

Страница 22: ...S report displays the total number of battery tests performed since the Tester was first used Press the LEFT and RIGHT ARROW keys simultaneously to clear the total and reset the starting date Transfer...

Страница 23: ...and printing the results of the Battery and System Tests To print the results align the analyzer s IR transmitter with the printer s receiver and select the PRINT soft key To return to the Main Menu p...

Страница 24: ...nd receiver are not aligned all the data may not print The infrared ports on the top of the analyzer and on the printer below the MODE button should be pointed directly at each other The maximum dista...

Страница 25: ...charge level declines The tester will display a warning message when the batteries need replacing Full Powered by test battery Decreasing Low Power Level Indicator for AA Batteries Replacing the Test...

Страница 26: ...by one or more U S and foreign patents For specific patent information contact Midtronics Inc at 1 630 323 2800 LIMITED WARRANTY This analyzer is warranted to be free of defects in materials and work...

Отзывы: