Midtronics B.V. Hoofdveste 6 - 8 Houten NL
www.midtronics.com
EXP-1000 HD
Chapter 8: QC test
The tester has the ability to test multiple batteries one after
the other without having to input the battery rating / settings.
There are two types of QC tests: the STOCK CONTROL or
COMPOUND TEST.
STOCK CONTROL is meant for batteries standing in a
warehouse or on a pallet where as COMPOUND TESTING is
done when the battery is in the vehicle.
1. Select the QC MODE
1
STOCK CONTROL
2
COMPOUND TEST
Press the NEXT soft key to continue. The BACK soft key
returns you to the Main Menu at the start of the test and
to the previous screen as you progress.
Stock control
2. The first screen shows you the amount of tests performed.
Once you press both the arrow keys you reset the test
counter. Press NEXT if you want to continue without clear-
ing the tests.
3. Select the BATTERY TYPE
1
REGULAR
2
AGM
3
SPIRAL
4
GEL
Press the NEXT soft key to continue.
4. Select the RATING UNITS
1
CCA
2
JIS
3
DIN
4
SAE
5
IEC
6
EN
Press the
NEXT
soft key to continue.
5. Select the BATTERY RATING
Press the UP ( ) and DOWN ( ) ARROW keys to select
the rating. In case of a JIS battery type the part number.
6. Enter the MINIMUM VOLTAGE.
7. Select the TEMPERATURE.
Aim the tester 5 cm from the sides or top of the battery
case. As soon as the temperature reading is stable the
operator can press NEXT.
The tester will now test the battery.
Compound test
2. The first screen shows you the amount of tests performed.
Once you press both the arrow keys you reset the test
counter. Press NEXT if you want to continue without clear-
ing the tests.
COMPOUND TEST
3. Select the BATTERY MENU.
1
MANUAL
2
PRE-SELECTION
MANUAL input is selecting the different battery parameters
that can be found on the battery. The PRE-SELECTION is what
is entered in the tester memory. This is initially empty but can
be filled in from the UTILITY menu.
Press the NEXT soft key to continue. The BACK soft key returns
you to the previous screen.
For selection of the MANUAL input see the previous
explanations and screens.
Chapter 8: QC test