Service manual
7
4. Specification
Model
MSE-07CR
MSE-07HR
MSE-09CR
MSE-09HR
Power supply
Ph-V-Hz
1,220-240V~,50Hz
1,220-240V~,50Hz
1,220-240V~,50Hz
1,220-240V~,50Hz
Capacity
Btu/h
7000
7000
9000
9000
Input
W
760
760
1000
1000
Rated current
A
3.5
3.5
4.6
4.6
Cooling
EER
Btu/wh
9.2
9.2
9.0
9.0
Capacity
Btu/h
8000
10000
Input
W
780
980
Rated current
A
3.6
4.4
Heating
COP
W/W
3.0
3.0
Max. input consumption
W
1000
1000
1300
1300
Max. current
A
5.0
5.0
6.3
6.3
Starting current
A
17.2
17.2
18.0
18.0
Model
2P14C225ANA
2P14C225ANA
2P18S225ANK
2P18S225ANK
Type
Rotary
Rotary
Rotary
Rotary
Brand
GD Matsushita
GD Matsushita
GD Matsushita
GD Matsushita
Capacity
Btu/h
7500
7500
9920
9920
Input
W
725
725
970
970
Rated current(RLA)
A
3.4
3.4
4.5
4.5
Locked rotor Amp(LRA) A
15
15
24
24
Thermal protector
B160-135-141E
MRA98854
External(MRA98745)
External(MRA98745
)
Capacitor
uF
25
25
30
30
Compressor
Refrigerant oil
ml
ATOMOS M60 270
ATOMOS M60 270
SUNISO 350
SUNISO 350
Model
RPG13H
RPG13H
RPG13H
RPG13H
Brand
Welling
Welling
Welling
Welling
Input
W
39.5
39.5
39.5
39.5
Capacitor
uF
1.2
1.2
1.2
1.2
Indoor fan
motor
Speed(hi/mi/lo)
r/min
1050/950/800
1050/950/800
1250/1100/850
1250/1100/850
Indoor air flow (Hi/Mi/Lo)
m3/h
400/35/300
400/35/300
450/400/350
450/400/350
Indoor noise level (Hi/Mi/Lo)
dB(A)
35/32/30
35/32/30
37/34/32
37/34/32
Model
YDK24-6T
YDK24-6T
YDK24-6T
YDK24-6T
Brand
Welling
Welling
Welling
Welling
Input
W
70
70
70
70
Capacitor
uF
3
3
3
3
Outdoor fan
motor
Speed
r/min
850
850
850
850
Outdoor air flow
m3/h
1500
1500
1800
1800
Outdoor noise level
dB(A)
49
49
50
50
Refrigerant type R22
g
530
570
580
800
Design pressure
MPa
2.6
2.6
2.6
2.6
Liquid side/ Gas side
mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
9.53
Max. refrigerant pipe
m
10
10
10
10
Refrigerant
piping
Max. difference in level
m
5
5
5
5
Plug type
16A
16A
16A
16A
Thermostat type
Electronic control
Electronic control
Electronic control
Electronic control
Operation temp
℃
17-30
17-30
17-30
17-30
Ambient temp
℃
18
~
-45
-7 -
~
45
18
~
-45
-7 -
~
45
Application area
m2
10-14
10-14
14-21
14-21
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally
somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.
Содержание MSE-07CR
Страница 1: ...Cover MSE 07CR MSE 07HR MSE 09CR MSE 09HR MSE 12CR MSE 12HR MSE 18CR MSE 18HR...
Страница 12: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Страница 14: ...Service manual 11...
Страница 15: ...Service manual 12 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Страница 16: ...Service manual 13 7 2 Wiring diagram MSE 07CR MSE 09CR MSE 12CR...
Страница 17: ...Service manual 14 MSE 07HR MSE 09HR MSE 12HR...
Страница 25: ...Service manual 22 discharged...