Service manual
41
13. Troubleshooting
13.1 Display board
Thi s indicator illuminates whe n the air conditioner i s in AUTO operation.
AU TO indicator
DE FROST indicator (F or Cooling & H eating mo dels only)
Thi s indicator illuminates whe n the air conditioner starts defrostin g automati cally or
when the warm air control fea ture is activated in he ating oper ation.
1
22
3
4
5
1
22
3
4
Dis plays the te mperature s ettings when the air c ondition er is operational.
This indicator fl ashe s after power is on and illum inate s when the unit is in oper ation.
This indicator il luminates when TIMER is set ON/OFF.
OPERATION in dicator
TIMER indicat or
TEMPERATUR E indicator
5
Signal receptor
13.2 Troubleshooting
For cooling mode:
Failure phenomenon
Operation
lamp
Timer
lamp
Indoor fan speed has been out of control for over 1 minute
☆
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
☆
On
Over current protection of the compressor occurs 4 times
X
☆
EEROM error
On
☆
No over-zero signal
☆
☆
r
Extinguish
☆
Flash at 5Hz
For heat pump mode:
Failure phenomenon
Operation
lamp
Timer
lamp
Defrosting
lamp
Over current protection of the compressor occurs 4 times
☆
X
☆
Indoor fan speed has been out of control for over 1 minute
X
☆
☆
No over-zero signal
☆
☆
☆
Temp. sensor on indoor evaporator is open circuit or short circuit
X
X
☆
Indoor room temp. sensor is open circuit or short circuit
X
☆
X
EEROM error
On
☆
X
r
Extinguish
☆
Flash at 5Hz
Содержание MSE-07CR
Страница 1: ...Cover MSE 07CR MSE 07HR MSE 09CR MSE 09HR MSE 12CR MSE 12HR MSE 18CR MSE 18HR...
Страница 12: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Страница 14: ...Service manual 11...
Страница 15: ...Service manual 12 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Страница 16: ...Service manual 13 7 2 Wiring diagram MSE 07CR MSE 09CR MSE 12CR...
Страница 17: ...Service manual 14 MSE 07HR MSE 09HR MSE 12HR...
Страница 25: ...Service manual 22 discharged...