Service manual
38
11.9 Auto mode
11.9.1
The air conditioner automatically selects one of the following operation modes: cooling, heating or
fan only according to the temperature
difference between room temperature (TA) and set temperature
(TS)
.
-1
TA-TS
2
Heating (fan only at cooling only)
Fan only
Cooling
11.9.2 The indoor fan blows automatically in corresponding selected mode.
11.9.3 The motion of indoor fan’s blade should accord with the selected operation mode.
11.9.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot
start for 15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect
when the set temp. varies.
11.10 Force cooling function
11.10.1 Select forced cooling function with the forced cooling button or the switch.
11.10.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is
set as low, the A/C operates at the DRY mode with a set temp. of 24
℃
.
11.10.3 All protections of remote control cooling are available at forced cooling operation.
11.10.4 Forced Auto function
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates at remote control mode with a set temp. of 24
℃
.
11.11 Sleep mode
11.11.1 The sleep function is available at cooling, heating or auto mode.
11.11.2 Cooling:
Содержание MSE-07CR
Страница 1: ...Cover MSE 07CR MSE 07HR MSE 09CR MSE 09HR MSE 12CR MSE 12HR MSE 18CR MSE 18HR...
Страница 12: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Страница 14: ...Service manual 11...
Страница 15: ...Service manual 12 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Страница 16: ...Service manual 13 7 2 Wiring diagram MSE 07CR MSE 09CR MSE 12CR...
Страница 17: ...Service manual 14 MSE 07HR MSE 09HR MSE 12HR...
Страница 25: ...Service manual 22 discharged...