8.7 Auto restart function 

In case of a sudden power failure, this function automatically sets the unit to previous 
settings before the power failure when power returns.   

 
8.8 Capacity test frequency locked. 

When test the cooling capacity, the frequency can be locked at Rated Frequency by 
following the below: 
1.    Set the indoor temp. to 17

  and high speed; 

2.    Push the outdoor check button for 5 seconds, then its frequency can be fixed at Rated 
Frequency. 

After the test is over, turn off the indoor to exit. 

When test the heating capacity, the frequency can be locked at 85Hz by following the 
below: 
1.    Set the indoor temp. to 30

  and high speed; 

2.    Push the outdoor check button for 5 seconds, then its frequency can be fixed at Rated 
Frequency. 

After the test is over, turn off the indoor to exit. 

 
8.9 Indoor unit indicator displayer   
 

8.9.1      OPERATION indicator  

This indicator flashes after power is on and illuminates when the unit is in operation. 
 

8.9.2      AUTO indicator 

This indicator illuminates when the air conditioner is in AUTO operation. 

 

8.9.3       TIMER indicator 

This indicator illuminates when TIMER is set ON/OFF. 

 

8.9.4        CLEAN AIR indication lamp 

Lights up when CLEAN AIR feature is activated and Ionizer can generate abundant anions 

to fill the room with refreshing and natural air. 

 

8.9.5       PRE.-DEF. Indicator (For Cooling & Heating models only) 

This indicator illuminates when the air conditioner starts defrosting automatically or when 

the warm air control feature is activated in heating mode. 

 

8.9.6       TURBO indication lamp  

Lights up when select TURBO function on cooling operation or on heating operation. 

 

8.9.7                  FREQUENCY indicator 

This indicator appears only when the compressor is in operation and indicates the current 

operating frequency. 

 

8.9.8       TEMPERATURE indicator 

Usually it displays the temperature settings. When change the setting temperature, this 

indicator begins to flash, and stops 20 seconds later.   

It displays the room temperature when the air conditioner is in FAN only operation.   

When the unit stops operation, it returns to original factory settings. 

Downloaded from AC-Manual.com Manuals

Содержание M2OA-18HRIN1

Страница 1: ...MULTI SPLIT TYPE HEAT PUMP AIR CONDITIONERS Technical service manual 2006 R410A Vertu Inverter multi Series Indoor Models MSV1I 09HRDN1 MSV1I 12HRDN1 Outdoor Models M2OA 18HRIN1 M3OA 27HRIN1 M40A 27HR...

Страница 2: ...cle diagram 4 Operation temperature limits 5 Indoor units combination 6 Wiring diagram 7 Wiring connection 8 Electric control functions 9 Troubleshooting Annex 1 Characteristic of temp sensor Annex 2...

Страница 3: ...ction at cooling mode 1 4 Anti cold air function at heating mode 1 5 Auto defrosting 1 6 Outdoor electric current protection 1 7 Temperature protection of the outdoor compressor top 1 8 Error self dia...

Страница 4: ...2 Dimensions 2 1 Indoor unit 2 2 Outdoor unit a Outdoor unit M2OA 18HRIN1 M3OA 27HRIN1 Dimension Mode W H D 9K 795 270 165 12K 845 286 165 Downloaded from AC Manual com Manuals...

Страница 5: ...5 335 845 b Outdoor unit M4OA 27HRIN1 Downloaded from AC Manual com Manuals...

Страница 6: ...valve EXV C Gas valve C Liquid valve A Gas valve D EXV C Capillary C Filter C Liquid valve D Indoor pipe out temp seneor D Coil temp sensor 3 2 Refrigeration circuit drawing of inverter trinary type L...

Страница 7: ...Capillary A Capillary B Exhaust temp sensor Indoor pipe out temp seneor A Indoor pipe out temp seneor B Filter A Filter B Outdoor Unit Main Capillary Check Valve Coil temp sensor 4 Operation Temperatu...

Страница 8: ...u h 9000 Btu h 12000Btu h 7000Btu h 9000 Btu h 7000Btu h 12000Btu h 9000Btu h 9000 Btu h 9000Btu h 12000Btu h 12000Btu h 12000Btu h 12000Btu h 18000Btu h 9000Btu h 18000Btu h 7000Btu h 18000Btu h 7000...

Страница 9: ...00Btu h 2 9000 Btu h 2 7000Btu h 2 9000 Btu h 12000 Btu h 7000Btu h 3 9000 Btu h 7000Btu h 3 12000 Btu h 7000Btu h 3 18000 Btu h 7000Btu h 4 9000Btu h 2 7000 Btu h 12000 Btu h 9000Btu h 3 7000 Btu h 9...

Страница 10: ...10 6 Wiring Diagram 6 1 Indoor unit 6 2 Outdoor unit M2OA 18HRIN1 Downloaded from AC Manual com Manuals...

Страница 11: ...11 6 3 Outdoor unit M3OA 27HRIN1 Downloaded from AC Manual com Manuals...

Страница 12: ...12 6 4 Outdoor unit M4OA 27HRIN1 Downloaded from AC Manual com Manuals...

Страница 13: ...ounding 1 0 Neoprene YZW300 500V Remark The connection wire between indoor unit and outdoor unit is standard And it is packaged in the indoor unit 7 2 Connection wire drawing 20 10 2 Neoprene YZW300 5...

Страница 14: ...than 25A the compressor stops 9 Outdoor condenser high temperature protection Under cooling mode if T3 65 for 3 minutes the compressor will stop When T3 52 the protection is not valid 10 Outdoor low t...

Страница 15: ...heating mode Indoor Fan can be set at HIGH MID LOW AUTO by using a remote controller but Anti cold wind function prevails Anti cold wind control function at heating mode Condition T Indoor exchanger...

Страница 16: ...cording to anti cold wind function in heating mode 4 Automatic operation mode The air conditioner automatically selects one of the following operation modes cooling heating or fan only according to th...

Страница 17: ...er than off time first turn off the A C it will be automatically on at set time and later be off at the set time then unit turns on at set time 5 Timer off on function off time is earlier than on time...

Страница 18: ...O indicator This indicator illuminates when the air conditioner is in AUTO operation 8 9 3 TIMER indicator This indicator illuminates when TIMER is set ON OFF 8 9 4 CLEAN AIR indication lamp Lights up...

Страница 19: ...vised capacity fan state No 1 evaporator pipe temp No 2 evaporator pipe temp No 3 evaporator pipe temp No 4 evaporator pipe temp outdoor pipe temp Outdoor temp discharge gas temp current of outdoor un...

Страница 20: ...ent temp rise 27 Low speed 25 High speed Ambient temp decline 25 Low speed When heating 14 Low speed Ambient temp rise 14 High speed 12 Low speed Ambient temp decline 12 High speed 8 13 Oil return fun...

Страница 21: ...upply electricity power still are kept in capacitors do not forget to discharge the electricity power in capacitor The value of resistance is about 1500 ohm to 2000 ohm Resistance The voltage in P3 an...

Страница 22: ...lanation E0 EEPROM error E1 No 1 Indoor units pipe temp sensor or connector of pipe temp sensor is defective E2 No 2 Indoor units pipe temp sensor or connector of pipe temp sensor is defective E3 No 3...

Страница 23: ...e shooting Display LED STATUS E0 EEPROM error Yes Temporarily turn off the power supply and turn it on again after 1 minute Does the trouble occur again Replace the indoor PCB Downloaded from AC Manua...

Страница 24: ...p sensor is defective Is connection to connector of pipe temp sensor good Check the resistance of the temp sensor according to Annex 1 Repair connector No Yes Replace the sensor Is connection to conne...

Страница 25: ...e temp sensor according to Annex 1 Repair connector No Yes Replace the sensor Yes Check the voltage of power supply if the voltage is about 220V turn off the power supply to indoor unit and turn it on...

Страница 26: ...d connection or defective when the voltage in outdoor is abnormal P3 and P4 310V DC P5 and P6 310V DC No Yes No Check the PC817 PC851 at Indoor main PCB and outdoor main board Normally Input voltage 5...

Страница 27: ...volume normal Gas charging Is abnormality the same after gas charging Refrigerant system such as clogging of capillary clogging of pipe etc Is protector on the top of compressor normal Normally the re...

Страница 28: ...door unit only Does the compressor start after 3 minutes Does the trouble occur again after compressor running some time No Yes No The compressor is defective Check the refrigerant circulation volume...

Страница 29: ...ly P N 1 0M P U 2 0M P V 2 0M P W 2 0M N W 1 0M N U 1 0M N V 1 0M Check compressor 1 Turn on the unit in cooling or heating in different season use a frequency meter to test the frequency in one of th...

Страница 30: ...ction When outdoor pipe temp is more than 65 C the unit will stop and unit runs again when outdoor pipe temp is less than 52 C Is the outdoor temp lower than 15 C Is the outdoor temp sensor right acco...

Страница 31: ...6 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2 5397 5 26 8778 32 7 2946 59 2 4468 6...

Страница 32: ...0V AC V W 60 150V AC P N DC 310V c Photo couple PC817 PC851 Control side 5V AC side 24V AC d S terminal and N changeable from 0 24V 2 Check the Diode Bridge component In wiring diagram rectifier Remar...

Отзывы: