20
8.12 Outdoor fan speed control
There is one fan with two-speed, the fan speed is controlled according ambient temp. After
the compressor stop, 30 seconds later the fan stops.
When cooling:
> 27
High speed
Ambient temp.rise
<27 Low
speed
>25 High
speed
Ambient
temp.decline
<25 Low
speed
When heating:
> 14
Low speed
Ambient temp.rise
<14 High
speed
>12 Low
speed
Ambient
temp.decline
<12 High
speed
8.13 Oil return function
If operation frequency is lower than 54Hz in 2 hours consecutively, it will be increased to
62Hz for 3 minutes. Then it recovers to the former operation frequency.