![Microtronics myDatalogNANO Ex Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/microtronics/mydatalognano-ex/mydatalognano-ex_user-manual_1789730068.webp)
9.2.1.4 Calculated channels
Note: The values of the calculated channels are directly calculated for every data output (display on the myDatanet
server or download from the myDatanet server). They are not saved in the server database.
9.2.1.4.1 Basis
Title 1-5
Freely selectable channel title for the calculated channels [0-16 characters]
Mode
Possible calculation modes for the calculated channels
Off
---
Calculated channel deactivated
Table
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]
Decimal
places
Number of decimal places that are used by all of the server display
elements
Digital
Invert
Inverts the input signal
+, -, x, / Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]
Decimal
places
Number of decimal places that are used by all of the server display
elements
Delta
Determines the difference between two measurement values and divides the result
by the time difference between the time stamps of the measurement values. The
time unit (value/sec., value/min., ...) for the result can be selected via the "Time
basis" parameter located in the "Calculation" tab. It is thus possible to convert the
meter reading (m
3
) of the source in to a flow rate (m
3
/min.) (see "Additional
explanation: Delta mode" on page 69).
Min
Defines the lower scale end of the pointer instruments
Max
Defines the upper scale end of the pointer instruments
Unit
String that is used as a measurement unit by all of the server display
elements [0-16 characters]
Decimal
places
Number of decimal places that are used by all of the server display
elements
68
Rev. 01
Содержание myDatalogNANO Ex
Страница 2: ......
Страница 8: ......
Страница 9: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 01 9 ...
Страница 10: ...2 1 Declaration of conformity Appendix 10 Rev 01 ...
Страница 11: ...Chapter 2 Declaration of conformity Rev 01 11 ...
Страница 12: ......
Страница 24: ......
Страница 52: ......
Страница 78: ......
Страница 86: ......
Страница 92: ......
Страница 104: ......
Страница 107: ...Chapter 17 Document history Chapter 17 Document history Rev Date Changes 01 10 09 2013 First version Rev 01 107 ...
Страница 108: ......
Страница 110: ......