Operating Instructions Thread tapping units/ Accessoriesr 01/09, Software 4.9
©
01.1994-2016 microtap GmbH
54
6.3.
Quality, error indications
A Status messages
EMERGENCY STOP
UNLOCK STOP BUTTON
SWITCH OFF UNIT
Meaning:
Remedy:
Emergency-Stop button is depressed
(only microtap II)
Unlock the Emergency-Stop button,
switch off the machine and switch on
again after 20 seconds.
SAFETY STOP
MOTOR LOCKED
Meaning:
Remedy:
Selector switch is set to „0“.
Set drive selector switch to „1“
(see also chapter “Changing tap”)
USER ABORTED
DEPTH 1/min M
4-5
0.10mm 1000R
0150NCM
Meaning:
Remedy:
User aborted thread tapping
Restart thread tapping after solving
the problem
COUNTER ACHIEVED
XXXX THREADS
DEPTH 1/MIN
M
4-5
0.10mm 1000R
0150NCM
Meaning:
Remedy:
Preset production quantity is reached.
Press illuminated associated push-
button.
xxx = Number of reversals
DEPTH 1/min M
4-5
0.10mm 1000R
0150NCM
Meaning:
Remedy:
In AUTO MODE the motorspindle is
not
in final position
Set so the adjusting lever, the motor
spindle drives herself in final position
also chapter “changing parameter /
start setup”.